Daikin ARQ Installation Manual

Daikin ARQ Installation Manual

Self-contained water source heat pump unit ventilator
Table of Contents

Advertisement

Daikin Self-Contained Water Source Heat Pump Unit Ventilator
Model ARQ - Standard Range
Model ERQ - Extended Range
Model GRQ - Geothermal Range
R-410A Refrigerant, MicroTech II™ ("F" Vintage)
©2013 Daikin Applied • www.DaikinApplied.com • (800) 432-1342
Before beginning installation, please read this publication in its entirety.
Develop a thorough understanding before starting the installation procedure.
This manual is to be used as a guide. Each installation is unique, so only general topics are covered.
The order in which topics are covered may not be those required for the actual installation.
Installation Manual
C
IMPORTANT!
IM 1083
Group: Unit Ventilator
Part Number: 106506250
Date: October 2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ARQ and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin ARQ

  • Page 1 IM 1083 Group: Unit Ventilator Part Number: 106506250 Date: October 2013 Daikin Self-Contained Water Source Heat Pump Unit Ventilator Model ARQ - Standard Range Model ERQ - Extended Range Model GRQ - Geothermal Range R-410A Refrigerant, MicroTech II™ (“F” Vintage) IMPORTANT! Before beginning installation, please read this publication in its entirety.
  • Page 3: Table Of Contents

    Data Plate - Specific Information .............4 Data Plate Location .................5 Make Piping Connections ...........22 Water Coil Connections ............22-23 Models ARQ, ERQ & GRQ Self-Contained Floor Unit System Balancing ................23 Ventilator Installation ............5 Receiving & Handling ..............5 Making Control Connections ..........24 Visible Loss or Damage ..............5...
  • Page 4: Nomenclature

    Table 1: Models ARQ, ERQ, GRQ Self-Contained Unit Ventilator (Floor Type) Data Plate - Specific Information Field Model E9 = Expanded Stand-Alone w/o TC w/CO 1. Product Category U = Unit Ventilator EA = Expanded Stand-Alone Master w/o TC w/CO EB = Expanded Stand-Alone Slave w/o TC w/CO 2.
  • Page 5: Data Plate Location

    Area – FT 3.37 (0.31) 4.20 (0.39) 5.08 (0.47) Quantity Approx. Ship Weight – Lbs. (KG) 690 (310) 720 (325) 760 (340) Refrigerant Charge – Oz. IM 1083 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ Page 5 of 42...
  • Page 6: Safety

    Although there is no PVC/CPVC piping in this product, please keep this in mind when selecting piping materials for your application, as system failure and property damage could result.” Page 6 of 42 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ IM 1083...
  • Page 7: Typical Floor Unit Installation

    Figure 6: Typical VentiMatic Shutter Assembly Installation (see installation section for typical warnings and cautions) VentiMatic Shutter Assembly Building Wall Louver Outside Unit Ventilator Outdoor Air Opening Outside Roomside Roomside Typical VentiMatic louver installation with shelving. IM 1083 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ Page 7 of 42...
  • Page 8: Meeting Ibc Seismic Requirements

    Meeting IBC Seismic Requirements In addition to all seismic requirements for IBC Certification listed elsewhere in the project specification, submittals for these units Daikin unit ventilators can be specified, as follows, to meet International include: Building Code seismic requirements: 1. A Certificate of Compliance from the Independent Certifying •...
  • Page 9: Wall Openings, Louvers & Venitmatic Shutter

    Shutter Vertical Louver with Flange, without Grille Self-Contained Floor Models ARQ, ERQ, GRQ are typically installed in front of a wall opening containing a properly sized louver that is designed to let in outside air while preventing water (such as rain) from getting past the louver and into the unit itself.
  • Page 10: Louver Installations With Typical Unit Arrangements

    Important: Gasket sealing surface is required. surface is required. CAUTION Accumulated moisture can cause property damage if not properly drained. Installing contractor must provide such drainage. Page 10 of 42 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ IM 1083...
  • Page 11: 21-7/8" Unit Depth

    Floor Line 1" Not More Important: Gasket sealing (25mm) Than 12" surface is required. Sealed Cement Mortar;Pitch Away Important: Gasket sealing From Unit surface is required. IM 1083 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ Page 11 of 42...
  • Page 12: Unit Depth

    Figure 20: Typical Louver Installation with Sloping Sealed Cement Mortar Base Wall Unit Louver Sealed Cement Mortar; Pitch Away From Unit Unit Gasket Caulk 1" (25mm) Floor Page 12 of 42 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ IM 1083...
  • Page 13 This helps prevent moisture from getting under the flashing and into the room. IM 1083 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ Page 13 of 42...
  • Page 14: Installing The Ventimatic Shutter Assembly

    (267) located behind shelf cabinets. Hardware to mount the interior 72" 75" ⁄ " ⁄ " 1500 (1829) (1905) (1832) (495) wall grille is not included. Page 14 of 42 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ IM 1083...
  • Page 15 Cabinet Outside Slotted Kickplate Outside Roomside Roomside Typical VentiMatic louver installation with shelving. IM 1083 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ Page 15 of 42...
  • Page 16: Preparing To Move The Unit

    Kickplate Tip forward until kickplate rests on floor Caster mounting cut-out Counter-clockwise to lower Clockwise to raise Left Caster Right Caster Page 16 of 42 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ IM 1083...
  • Page 17: Reversing Condensate Drain End

    2. Spray water into the drain pan on the high end to wash debris to the low end (drain end). Models ARQ, ERQ and GRQ condensate drain connection is on the 3. Remove any debris, making sure that the drain holes are not left end (with static equalizer cover).
  • Page 18 Secure the wall fasteners to prevent the unit ventilator from moving and tipping over Figure 35: Unit Mounting Holes Locations Unit Mounting Holes ″ ″ ″ ″ Page 18 of 42 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ IM 1083...
  • Page 19: Operating Limits

    Extended range units may combine any two maximum or minimum conditions, but not more than two, with all other conditions being normal conditions. IM 1083 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ Page 19 of 42...
  • Page 20: Piping Considerations

    1⁄4" per foot. The unit drain pan has a 7/8 inch O.D. drain connection to accommodate the condensate drain hose. Page 20 of 42 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ IM 1083...
  • Page 21: Water System Cleaning

    NOTICE Runouts Initially Connected Together It is Daikin’s policy not to make recommendations on water treatment. It is the responsibility of the user to check that Bypass valves at the heat rejector and supplementary water heater the water supply to the units is free of contaminants or cor- should be adjusted for normal operation.
  • Page 22: Make Piping Connections

    This permits easy removal of the coil or control valve if servicing is required. Page 22 of 42 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ IM 1083...
  • Page 23: System Balancing

    GPM and the measured flow rate was 15 GPM, then its proportionate flow rate would be 1.5. Figure 41: Typical System Balancing Circuit Typical water system consisting of reverse return mains feeding branch circuits IM 1083 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ Page 23 of 42...
  • Page 24: Making Control Connections

    The LUI features a 2-digit display, 7 keys (1 key is hidden), and 9 individual LED indicators. See “Local User Interface” for further details. Figure 42: MicroTech II Sensor and Component Locations (Top View) for AR, ER & GR Page 24 of 42 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ IM 1083...
  • Page 25 Refer to the “UVC Input and Output Tables” in IM 739 for available options. Figure 45: Top View - Local User Interface Compartment IM 1083 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ Page 25 of 42...
  • Page 26 (default of 120 minutes). This time can be set in 1-minute increments from 1 minute to 240 minutes through the Unit Ventilator Service Tool or a network. Page 26 of 42 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ IM 1083...
  • Page 27: Typical Wiring Diagram

    Typical Wiring Diagram IM 1083 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ Page 27 of 42...
  • Page 28: Electical Data

    Electrical Data Table 11: Model ARQ, ERQ, GRQ Electrical Data – Size 024 Voltage Range Compressor Heating Options Power Supply Room Voltage Heater Heater Maximum Min. Max. Auxiliary Heat Type Amps Fuse Refrigerant Heating – – 1 7.0 208/60/1 11.4 52.0...
  • Page 29: Size 048

    Electrical Data Table 13: Model ARQ, ERQ, GRQ Electrical Data – Size 048 Voltage Range Compressor Heating Options Power Supply Room Voltage Heater Heater Maximum Min. Max. Auxiliary Heat Type Amps Fuse Refrigerant Heating – – 32.2 208/60/1 23.6 96.0 Low (3-elem.)
  • Page 30: Microtech Ii Unit Electical Connections

    Unit Main Power On/Off Switch Grommeted Power Wire Entry Main Power On/Off Switch Ground Lug Note: B not used on single phase. Page 30 of 42 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ IM 1083...
  • Page 31 Option 1 Device Option 3 Device (by others) (by others) (by others) Ventilation Lockou t Unoccupied (default) Remote (default) or or Dewpoint Humidity Shutdown Exhaust Interlock IM 1083 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ Page 31 of 42...
  • Page 32: Microtech Ii Remote Wall-Mounted Sensor

    UVC. 18 AWG 310 ft. (94 m) 20 AWG 200 ft. (61 m) 22 AWG 125 ft. (38 m) Page 32 of 42 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ IM 1083...
  • Page 33 (80 x 80 mm [3.15 x 3.15 in.]) mounting Unit Mounted Temperature Sensor base (1) with attached terminal block (1) • cover slider insert with printed logo for Daikin (1) • No. 6-32 x 1 in. flat-head screw (2) •...
  • Page 34 5. Drill a 35 mm (1-3/8 in.) hole in the surface where the sensor will 5. Pull the cable or wiring through the hole. be mounted. Page 34 of 42 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ IM 1083...
  • Page 35 Figure 65: 111048101 Sensor Wiring Terminal Block on 111048101 Sensor Repairs and Replacement No repair options available. Call your local Daikin representative for sensor replacement. IM 1083 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ Page 35 of 42...
  • Page 36: Electromechanical Unit Wire Connections

    Term Conn. Factory Wired Capped Wire Ground Figure 69: Typical ElectroMechanical Wiring Diagram - Model AR, Thermostat Control with Normally Open Heat, 460 Volt - 3Phase Page 36 of 42 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ IM 1083...
  • Page 37: Installing (Optional) End Panel

    Installing (Optional) End Panel End Panel Dimensions Figure 70: 1" (25mm) and 6" (152mm) End Panel Dimensions – ARQ, ERQ & GRQ Self-Contained Floor Unit Ventilators All Dimensions 16⅝" (422mm) Deep 21⅞" (556mm) Deep in Inches End Panels End Panels "...
  • Page 38: Piping Stub-Up Details, 6' End Panel

    1/4"- 20 Tinnerman Nut, Clip Oxford Brown Kickplate, Factory Assembled 1/4"- 20 × 1/2" over Lower Hole in Unit Base to Base of End Panel Screw Steel Kickplate Page 38 of 42 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ IM 1083...
  • Page 39: Prepare Unit Ventilator For Start-Up

    Unit size 048 has a fan shaft bearing located between the first structural frame and renewable Amerglas media. and second fan from the unit left end that is required to be oiled. IM 1083 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ Page 39 of 42...
  • Page 40: Prepare For Start-Up

    Protect your investment - read carefully that proper start-up was completed. Your Daikin express written limited warranty does not cover equipment The form is enclosed in the manila envelope located behind the left failures that are caused by misuse, abuse, mis-installation, failure to front access door.
  • Page 41: Troubleshooting

    13256-1 and tested at these conditions. WARNING Recycle/recovery equipment must be designated for R-410A. R-410A pressure is greater than R-22. Improper equipment can cause severe injury or death. IM 1083 Self-Contained WSHP Unit Ventilator Models ARQ, ERQ, GRQ Page 41 of 42...
  • Page 42: Troubleshooting Refrigeration Circuit

    Low Temp Daikin Training and Development Now that you have made an investment in modern, efficient Daikin equipment, its care should be a high priority. For training information on all Daikin HVAC products, please visit us at www.DaikinApplied.com and click on training, or call 540-248-9646 and ask for the Training Department.