Daikin GYEQ20AN Service Manual page 97

Gas heat pump air conditioner heat recovery r-410a 50 hz
Table of Contents

Advertisement

SiAUY361411EA
Outdoor unit
Run
display
Lamp
-
On
E0
Blinking
E1
Blinking
E2
Blinking
E3
Blinking
E4
Blinking
E6
Blinking
E7
Blinking
E9
Blinking
EA
Blinking
EH
Blinking
F0
Blinking
F2
Blinking
F3
Blinking
F4
Blinking
F6
Blinking
F7
Blinking
F9
Blinking
FH
Blinking
FJ
Blinking
H0
Blinking
H1
Blinking
H6
Blinking
J1
Blinking
J2
Blinking
J3
Blinking
J5
Blinking
J6
Blinking
J7
Blinking
J8
Blinking
J9
Blinking
JA
On
JA
Blinking
JH
Blinking
JJ
Blinking
JF
Blinking
L1
Blinking
On
L8
Off
On
L8
Off
LE
Blinking
LF
Blinking
On
-
Off
On
-
Off
On
-
Off
On
-
Off
P0
Blinking
Device Overview
GYEQ Models
Inspection
Unit
Remote control
display
No.
display
Off
Blinking
CJ
Blinking
Blinking
E0
Blinking
Blinking
E1
Blinking
Blinking
E2
Blinking
Blinking
E3
Blinking
Blinking
E4
Blinking
Blinking
E6
Blinking
Blinking
E7
Blinking
Blinking
E9
Blinking
Blinking
EA
Blinking
Blinking
EH
Blinking
Blinking
F0
Blinking
Blinking
F2
Blinking
Blinking
F3
Blinking
Blinking
F4
Blinking
Blinking
F6
Blinking
Blinking
F7
Blinking
Blinking
F9
Blinking
Blinking
FH
Blinking
Blinking
FJ
Blinking
Blinking
H0
Blinking
Blinking
H1
Blinking
Blinking
H6
Blinking
Blinking
J1
Blinking
Blinking
J2
Blinking
Blinking
J3
Blinking
Blinking
J5
Blinking
Blinking
J6
Blinking
Blinking
J7
Blinking
Blinking
J8
Blinking
Blinking
J9
Off
Blinking
JA
Blinking
Blinking
JA
Blinking
Blinking
JH
Blinking
Blinking
JJ
Blinking
Blinking
JF
Blinking
Blinking
L1
On
Off
Off
On
Blinking
L8
Blinking
Blinking
LE
Blinking
Blinking
LF
Blinking
Blinking
M1
Blinking
Blinking
M8
Blinking
Blinking
MA
Blinking
Blinking
MC
Blinking
Blinking
P0
2 How to Perform a Test Run
Error
Indoor Unit - Remote Control Sensor Failure
Engine Start is Faulty
Engine Overspeed
Engine Stall
Oil Pressure Too Low
Abnormal Cooling Water Temperature
Abnormal Discharge Temperature
Abnormal High Pressure
Abnormal Low Pressure
EEPROM Malfunction
Software Version Mismatch / PCB Mismatch
Starter System Failure
Outdoor Fan Failure
Oil Pressure Switch Failure
Cooling Water Temperature Sensor Disconnected/Shorted
Discharge Temperature Sensor Disconnected/Shorted
Engine Room Temperature Abnormal
Insufficient Refrigerant
Insufficient Compressor Oil Detected
Abnormal High Differential Pressure
Misfire Detected
Clutch Failure
Indoor Unit Electronic Expansion Valve Failure
Air-Fuel Ratio Controller Failure
Intake Air Temperature Sensor Disconnected/Shorted
Outdoor Air Temperature Sensor Disconnected/Shorted
Outdoor Unit Electronic Expansion Valve Failure
Oil Return Solenoid Valve Failure
High Pressure Sensor System Failure
Exhaust Temperature Sensor Disconnected
Low Pressure Sensor Disconnected/Shorted
Compressor Automatic Emergency Run (during continued running)
Compressor Automatic Emergency Run
Pressure Sensor Failure
Oil Temperature Sensor Disconnected/Shorted
Receiver Temperature Sensor System Failure
Exhaust Temperature Abnormal
Periodic Inspection Reminder (not an error message)
If 200 or less hours remain before the next periodic inspection
Periodic Inspection Reminder (not an error message)
If the periodic inspection time has passed
Starter Relay Failure
BS Unit Circuit Switch Failure
Centralized Controller P Board Failure
Transmission Failure Among Centralized Controllers
Centralized Controller Mismatch
Centralized Controller Address Incorrect
Too Many Indoor Units Connected
– 19 –
Test Run Manual
0FGHP-EN0841 DGJ002
86