User reference guide Daikin Altherma 3 R F EHVZ04S18DA6V(G) EHVZ08S18DA6V(G) EHVZ08S23DA6V(G) EHVZ08S18DA9W(G) EHVZ08S23DA9W(G) EHVZ04S18DJ6V(G) EHVZ08S18DJ6V(G) EHVZ08S23DJ6V(G) User reference guide EHVZ08S18DJ9W(G) English Daikin Altherma 3 R F EHVZ08S23DJ9W(G)
Symptom: The system is making gurgling noises after capabilities or lack of experience and knowledge if they have been commissioning................19 given supervision or instruction concerning use of the appliance in 8 Relocation User reference guide EHVZ04+08S18+23DA + EHVZ04+08S18+23DJ Daikin Altherma 3 R F 4P495251-1B – 2019.06...
Latest revisions of the supplied documentation may be available on NOTICE the regional Daikin website or via your installer. ▪ Do NOT place any objects or equipment on top of the The original documentation is written in English. All other languages unit.
▪ User or Advanced user: 15 min ▪ Installer: 1 h Dials and buttons You use the dials and buttons: User reference guide EHVZ04+08S18+23DA + EHVZ04+08S18+23DJ Daikin Altherma 3 R F 4P495251-1B – 2019.06...
▪ ▪ : Radiator g2 Leaving water temperature setpoint g3 Room thermostat type: Home screen ▪ : Daikin user interface used as room Main menu screen Lower level screens: thermostat c1: Setpoint screen ▪ : External control c2: Detailed screen with values c3: Screen with weather-dependent curve ▪...
The setup of the unit is displayed in a schematic way. See "4.2.1 Home screen" on page 5 for more information. User reference guide EHVZ04+08S18+23DA + EHVZ04+08S18+23DJ Daikin Altherma 3 R F 4P495251-1B – 2019.06...
Room thermostat type of the main zone: If b=… Then the temperature control is… Main zone Additional zone (if any) Room thermostat External room control thermostat control External room thermostat control EHVZ04+08S18+23DA + EHVZ04+08S18+23DJ User reference guide Daikin Altherma 3 R F 4P495251-1B – 2019.06...
Depending on the DHW tank mode (installer setting), you use a different domestic hot water control: ▪ Reheat only 15°C ▪ Schedule + reheat 00:00 07:00 14:00 21:00 ▪ Schedule only DHW tank temperature Time User reference guide EHVZ04+08S18+23DA + EHVZ04+08S18+23DJ Daikin Altherma 3 R F 4P495251-1B – 2019.06...
In Reheat only mode, you can use the tank temperature setpoint screen to read out and adjust the domestic hot water temperature. 1 Go to [5]: Tank. Tank EHVZ04+08S18+23DA + EHVZ04+08S18+23DJ User reference guide Daikin Altherma 3 R F 4P495251-1B – 2019.06...
An incentive can be taken into account when setting the energy prices. Although the running cost can increase, the total operation cost, taking into account the reimbursement will be optimized. EHVZ04+08S18+23DA + EHVZ04+08S18+23DJ User reference guide Daikin Altherma 3 R F 4P495251-1B – 2019.06...
Heating schedule heating mode. [3.2] Additional zone > Program the desired leaving water Heating schedule temperature for the additional zone in heating mode. User reference guide EHVZ04+08S18+23DA + EHVZ04+08S18+23DJ Daikin Altherma 3 R F 4P495251-1B – 2019.06...
Page 13
1 Select Monday. User defined 1 User defined 1 4 Select Paste. 2 Select Edit. Delete Edit Delete Copy Edit Paste Copy Result: User defined 1 EHVZ04+08S18+23DA + EHVZ04+08S18+23DJ User reference guide Daikin Altherma 3 R F 4P495251-1B – 2019.06...
Not all schedules can be renamed. Usage example: You work in a 3-shift system If you work in a 3-shift system, you can do the following: User reference guide EHVZ04+08S18+23DA + EHVZ04+08S18+23DJ Daikin Altherma 3 R F 4P495251-1B – 2019.06...
Page 15
The symbol shown here corresponds to the heat emitter for that zone: ▪ : Underfloor heating ▪ : Fan coil unit ▪ : Radiator ▪ : Domestic hot water tank EHVZ04+08S18+23DA + EHVZ04+08S18+23DJ User reference guide Daikin Altherma 3 R F 4P495251-1B – 2019.06...
About Connection status User profile Operation Room Space heating/cooling Tank Setpoint screen INFORMATION Depending on the selected installer settings and unit type, settings will be visible/invisible. User reference guide EHVZ04+08S18+23DA + EHVZ04+08S18+23DJ Daikin Altherma 3 R F 4P495251-1B – 2019.06...
The refrigerant inside this unit is mildly flammable. temperature and do NOT let the room temperature drop too low. It will take more time and energy to heat up the room again. EHVZ04+08S18+23DA + EHVZ04+08S18+23DJ User reference guide Daikin Altherma 3 R F 4P495251-1B – 2019.06...
1 Go to [8.2]: Information > Malfunction history. automatically take over the heat load. You see a list of the most recent malfunctions. User reference guide EHVZ04+08S18+23DA + EHVZ04+08S18+23DJ Daikin Altherma 3 R F 4P495251-1B – 2019.06...
Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation. Relocation Field supply Equipment NOT made by Daikin that can be combined with product according instructions Overview: Relocation accompanying documentation.