1.3.1 Outdoor Units
(1) Enter RUN mode, select CH [1] in Level 1 and press
2 and press
Level 3, the data is displayed.
Table 4.4/ (List of outdoor unit data)
CH
Item
01
Current speed
02
Target speed
03
Speed set-point
04
Throttle valve
05
Fuel control valve
06
Mode-flag
07
EV1
08
EV2
09
EV3
10
EV4
11
EV5
12
EV6
13
Water motor valve
14
Fan 1
15
Fan 2
16
Fan 3
17
Cooling water pump
18
Cooling water temperature
19
High-side pressure 1
20
Low-side pressure
21
Outdoor air temperature
22
Exhaust temperature
23
Discharge temperature 1
24
Discharge temperature 2
25
Intake temperature 1
26
Intake temperature 2
27
Intake temperature 3
28
Intake temperature 4
29
Oil temperature 1
30
Oil temperature 2
31
(Reserved for future use)
32
(Reserved for future use)
33
(Reserved for future use)
34
(Reserved for future use)
∗ If your selected channel contains an item that is not supported by the unit model, the LCD
Fig. 4.5/ (Content of outdoor unit segment display)
Segment 0
Segment 1
CH number display
Troubleshooting
Outdoor unit data display
. (3) When the CH (Table 4.4) of the desired data item is selected in
NEXT
Content
min
min
min
pulse
pulse
4th digit: 0, normal
mode; 1, checker mode
3rd digit: 0, stop; 1,
operation
2nd digit: 0, blowing; H,
heating; C, cooling
1st digit: 0, auto; 2,
manual
pulse
pulse
pulse
pulse
pulse
pulse
pulse
min
min
min
min
°C
MPa
MPa
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
displays nothing or "-".
Segment 2
4th digit
CH
-1
35
Circuit board temperature
-1
36
Not used
-1
37
(Reserved for future use)
38
(Reserved for future use)
39
Not used
40
(Reserved for future use)
41
Not used
42
Not used
43
Not used
44
SHS1
45
SHS2
46
SHS3
47
SHS4
48
SHD1
49
SHD2
50
SHO1
-1
51
SHO2
-1
52
(Reserved for future use)
-1
53
High pressure converted temperature 1
-1
54
(Reserved for future use)
55
Low pressure converted temperature
56-59 Not used
60
Receiver temperature 31
61
Intake temperature 5
62
Oil temperature 3
63
Oil temperature 4
64
(Reserved for future use)
65
SHS5
66
SHO3
67
SHO4
68
(Reserved for future use)
69
High-side pressure 2
70
High-side pressure 3
71
High-side pressure 4
72
EV3A
73
EV3B
74
EV7
Segment 3
3rd digit
Actuator status display
Troubleshooting the Outdoor Unit
NEXT
. (2) Select CH [01] in Level
Item
Content
Segment 4
Segment 5
2nd digit
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
MPa
MPa
MPa
pulse
pulse
pulse
1st digit