6. Remove the engine mount on the front left side.
7. Remove the V ribbed belt. (See page 213 [1.2 Periodic Inspection Procedure for the
8. Place wooden bases underneath the compressor.
9. Remove all the harnesses and hoses (cooling, intake, exhaust, fuel, and lubricating oil) that
10.Remove the air cleaner and drain filters.
11.∗ Remove the front comp bracket and remove the bolts that anchor the back comp bracket
12.Remove the engine mount on the front right side.
13.Pull out the engine.
[Reverse the steps above to install the replacement]
∗ Make sure that the types and sizes (length in particular) of the bolts and nuts are correct.
2.2

Replacing the Compressor

Fig. 6.3/ Compressor periphery structure diagram
Replacement of Parts
Outdoor Unit].)
(Use two wooden bases sized approximately 45 × 700 mm.)
∗ Fit the compressor with the wooden bases from beneath the front comp bracket to the
back comp bracket.
are connected to the engine.
to the engine.
∗ Take care to prevent the compressor from slipping down from the wooden bases when
pulling it out. Once you have pulled out the compressor, take care not to drop it.
Large round M10 x 30
Back comp support
Guard M10 x 30
Upper comp bracket
Front left side engine mount
Guard M10 x 16
Replacement of Primary Parts
Back comp bracket
Engine fixture
spring M10 x 25
Front comp bracket
023433-00E01