26.13 DIGITAL INPUTS

This menu lets you set the digital inputs.
MENU
PAR
26.13.01
11152
26. 13.02
11154
26. 13.03
11156
26. 13.04
11158
26. 13.05
11160
26. 13.06
11162
26. 13.07
11164
26. 13.08
11166
26. 13.09
11168
26. 13.10
11180
26. 13.11
11194
26. 13.12
11196
Parameters source "src" can be assigned to any digital input.
If the source is used to enable a function, for example Anti Sway, you can set the value of Anti sway src =
One. In this case, the function is always active.
ADV200-HC Manual
Description
FWD cmd src
Digital input for Forward command.
REV cmd src
Digital input for Reverse command.
Multi spd 1 src
Digital input for multispeed 1 command.
Multi spd 2 src
Digital input for multispeed 2 command.
Jstk Zero pos src
Digital input for joystick ZERO position.
Anti Impact src
Digital input to activate Anti Impact.
Limit switch src
Digital input for limit switch contacts.
Brake fbk src
Digital input for brake feedback.
ELS src
Digital input to activate following.
Input to be set only on drives configured as ...-ELS-VM, ...-ELS.
Reset src
Digital input for Reset alarms command.
Anti sway src
Digital input to activate Anti Sway.
ELS align src
Digital input to activate alignment of drives in Electric Shaft.
Input to be set only on drives configured as ...-ELS-VM, ...-ELS.
UM
Type
Def
*
ENUM
Dig inp1
*
ENUM
Dig inp2
*
ENUM
Dig inp3
*
ENUM
Dig inp4
*
ENUM
Dig inp5
*
ENUM
Dig inp1X
*
ENUM
Dig inp2X
*
ENUM
Dig inp3X
*
ENUM
Dig inp4X
*
ENUM
Dig inp5X
*
ENUM
Dig inp6X
*
ENUM
Dig inp7X
Min
Max
ACCESS
*
*
R/W
*
*
R/W
*
*
R/W
*
*
R/W
*
*
R/W
*
*
R/W
*
*
R/W
*
*
R/W
*
*
R/W
*
*
R/W
*
*
R/W
*
*
R/W