26.15 ANALOG INPUTS

This menu contains the analog input settings.
MENU
PAR
26.15.01
11104

26.16 ALARM CONFIG

This menu contains the application alarm settings.
The action of an alarm depends on how its "Action" parameter was set:
Signal
Warning
None
Warning
X
Alarm
MENU
PAR
26. 16.01
11022
26. 16.02
11066
26. 16.03
11086
26. 16.04
11088
26. 16.05
11090
26. 16.06
11098
26. 16.07
11126
ADV200-HC Manual
Description
Speed ref src
Analog input for setting speed reference.
Reset Condition
Alarm
Automatic, when fault
condition is eliminated
X
Manual
Description
Brake fbk time
Maximum time allowed from sending of brake command to reception of brake feedback.
If, after the set time, the FW detects that the feedback state does not match the command, the
action provided in "BRAKE FBK action" is activated.
Brake fbk action
Action to be taken if brake feedback does not match command within time set in "Brake fbk
time"..
Jstk time
Maximum allowed time for reception of multiple commands from joystick.
If, after the set time, the software detects multiple commands (ex: FWD + REV) the action
provided in "Jstk action" is activated.
Jstk action
Action to be taken if software detects multiple commands for a time exceeding "Jstk time".
AI time
Maximum allowed time after which, if torque ( drive in FOC CL and FOC OL mode) or current
(drive in V/f mode) exceeds the impact threshold set in "AI Thr," the action provided in "AI
action" is activated.
AI action
Action to be taken if software detects that torque (current) exceeds the impact threshold for a
time set in "AI time".
OL1 time
Maximum allowed time after which, if torque (in FOC CL and FOC OL mode) or current (in V/f
mode) exceeds the Overload threshold set in "OL1 Load thr," the action provided in "OL1
action" is activated
UM
Type
Def
*
ENUM
Analog
inp 1
Drive
Normal operation
Normal operation
Disabled
UM
Type
Def
ms
FLOAT
400
*
ENUM
Alarm
ms
FLOAT
400
*
ENUM
Alarm
ms
FLOAT
500
*
ENUM
Alarm
ms
FLOAT
100
Min
Max
ACCESS
*
*
R/W
Brake
Normal operation
Normal operation
Closed
Min
Max
ACCESS
0
10000
R/W
*
*
R/W
0
10000
R/W
*
*
R/W
0
10000
R/W
*
*
R/W
0
10000
R/W