If the "ZERO CROSSING" function is enabled, the reversal of direction is blocked without closing of the
brake; when a command in the opposite direction is received during movement, if the "ZERO CROSSING"
function is enabled the close brake sequence is activated, the brake remains closed for a time equal to "Zero
Crossing delay," after which the brake is opened and the new command is executed.
MENU
PAR
26.03.01
11012
26.03.02
11014
26.03.03
11034
26.03.04
11100
26.03.05
11110
The "ZERO CROSSING" function cannot be enabled on drives configured as ..-ELS-M, ...ELS
ADV200-HC Manual
Description
FWD cmd keeping
Command keeping time in FWD direction.
REV cmd keeping
Command keeping time in REV direction.
Min time cmd jstk
Minimum keeping time of a command, beyond which the command is executed.
Zero crossing
Enabling of Zero Crossing function.
Zero crossing delay
Delay for restart after brake close for reversal of direction.
UM
Type
Def
ms
FLOAT
0
ms
FLOAT
0
ms
FLOAT
10
*
BOOL
Off
ms
FLOAT
200
Min
Max
ACCESS
0
5000
R/W
0
5000
R/W
0
1000
R/W
*
*
R/W
0
5000
R/W
Page 14 of 55