gefran ADV200-HC Instruction Manual page 21

Table of Contents

Advertisement

MENU
PAR
26.06.01
11024
26.06.03
11070
26.06.04
11072
26.06.05
11076
26.06.06
11078
26.06.07
11080
26.06.08
11082
26.06.09
11102
26.06.10
11170
ADV200-HC Manual
Description
Speed Up Selector
Selector to enable the HOIST SPEED UP or POWER SPEED UP function.
0 none
1 Speed up
2 Power up
Spd up FWD trq thr
SPEED UP
Threshold (FWD), used to determine if handled load is "light."
In V/f mode, the parameter is a % of nominal current of the motor.
In FOC CL or FOC OL mode, the Spd up FWD thr parameter is a % of nominal torque of the
motor.
Spd up FWD speed
SPEED UP
Speed reference (FWD) used after it is determined that the load is "light".
Spd up REV trq thr
SPEED UP
Threshold (REV), used to determine if handled load is "light."
In V/f mode, the parameter is a % of nominal current of the motor.
In FOC CL or FOC OL mode, the parameter is a % of nominal torque of the motor.
Spd up REV speed
SPEED UP
Speed reference (REV) used after it is determined that the load is "ligh.".
Spd up Test time
SPEED UP
Duration of test, during which it is determined that the torque (current) delivered (absorbed) by
the motor is below "Spd up FWD(REV) thr."
!! ATTENTION!!
If the entered value is too high, the test may take longer than necessary and slow the
operations.
Spd up test speed
SPEED UP
Speed temporarily maintained during the test.
PWR UP FWD pwr ref
POWER UP
This is the maximum power to be delivered to lift the load. Net of friction it equals the product
of:
Mass[kg]*9.81*linear speed of load [m/s]
It refers to motor power.
This parameter refers to the rise, where the load helps braking. The set default value refers to
a lift system where at nominal load 50% of motor torque is used to support the load and 50%
for acceleration.
PWR UP REV pwr ref
POWER UP
This is the maximum power to be delivered to lower the load. Net of friction it equals the product
of:
UM
Type
Def
ENUM
none
%
INT
30
rpm
FLOAT
3000
%
INT
30
Rpm
FLOAT
3000
ms
INT
600
rpm
FLOAT
700
%
INT
90
%
INT
50
Min
Max
ACCESS
*
*
R/W
0
200
R/W
0
6000
R/W
0
200
R/W
0
6000
R/W
0
10000 R/W
0
6000
R/W
0
120
R/W
0
120
R/W
Page 21 of 55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Adv200 asyAdv200 syn