Anti Impact - gefran ADV200-HC Instruction Manual

Table of Contents

Advertisement

26.10 ANTI IMPACT

This function prevents damage if the load strikes an obstacle.
The function can be activated by the operator via digital input, and is active after the drive has been enabled
and the brake has been opened.
Once activated, the speed reference is changed to the value indicated in the "AI speed" parameter.
If a change in torque (drives configured in FOC CL and FOC OL mode) or in current (drives configured in V/f
mode) greater than "AI Thr" is detected during operation, the programmed action is commanded.
The action to be taken if thresholds is exceeded is specified in the "Al time" and "Al Action" parameters on the
ALARM CONFIG menu.
Note: If you use –ELS (electric shaft) configuration):
 La soglia viene impostata in % sul solo drive definito come "master virtuale" ...–ELS-VM. The "virtual
master" receives the load %s of each shaft from the slaves.
 The action if the threshold is exceeded must be specified only on drive...–ELS-VM.
 The function activation status will be shown on the monitor of drive ...-ELS-VM
ADV200-HC Manual
Page 29 of 55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Adv200 asyAdv200 syn

Table of Contents