Firmware; Alarms - gefran ADV200-HC Instruction Manual

Table of Contents

Advertisement

26.17 FIRMWARE

Read-only menu showing the application version and release.
MENU
PAR
26.17.01
12102

4.1 ALARMS

The table shows the alarms for the application, displayable on the keypad.
DISPLAY
PARAMETERS
JOYSTICK
BRAKE
OVERLOAD 1
OVERLOAD 2
IMPACT
LIMIT SWITCH
ELS FAULT
HL FAULT
SLAVE FAULT
ADV200-HC Manual
Description
Version
Application version.
DESCRIPTION
Parameter setting error
Error in commands received from
joystick or button panel.
Inequality detected between brake
command and feedback beyond
allowed time.
Overload detected
Overload detected
Impact detected.
Limit switch tripped.
ONLY FOR ...-ELS-VM DRIVE
Position error threshold between
Virtual Master and commanded shaft
exceeded
ONLY FOR ...-HL-M DRIVE
Torque error threshold between master
motor and slave motor exceeded
ONLY FOR ...-ELS-VM or ...-HL-M
DRIVE
"Slave" drive in alarm or "slave" drive
has not executed command to
open/close brake or to enable drive.
UM
Type
Def
*
INT
*
OPERATION
Check parameter settings.
Check that no multiple commands are entered.
Check wiring and setting of joystick or button panel.
Check brake feedback wiring or setting of "ALLARM
CONFIG\Brake fbk time" parameter.
Check load weight or setting of OVERLOAD function
parameters.
Check load weight or setting of OVERLOAD function
parameters.
Check if load has struck an obstacle or check setting
of ANTI IMPACT function parameters.
You can move only in the direction opposite that of
the tripped limit switch.
Check cause of fault on "slave" drive.
Check cause of fault on "slave" drive.
Check cause of fault on "slave" drive.
Min
Max
ACCESS
*
*
R
Page 43 of 55