Sharp MX-2314N Service Manual page 312

Digital full color multifunctional system
Hide thumbs Also See for MX-2314N:
Table of Contents

Advertisement

Section/
Unit work
Section name
Unit name
sequence
10
Fusing
Fusing unit
section
11
Other
* 1: Note for cleaning the image registration/density sensor.
When in maintenance or in case a service call, refer to "Criteria for necessary of cleaning" below to judge the necessity of cleaning the image
registration/density sensor. If it is judged that cleaning is necessary, then perform cleaning
Criteria for necessity of cleaning
• The SIM44-2 item D/E/F value is increased by aging or dirt of the image density sensor.
• When the image density is decreased, execute SIM44-2 and execute SIM46-74 Copy balance adjustment.
Greasing
Greasing is not always required for every maintenance. In the fol-
lowing cases, check and grease.
• When there are some noises.
• When a lot of jams occur frequently. (Check the jam history.)
For the part code of grease to be used, refer to "[15] TOOL LIST."
Cleaning of sensors and detectors in the paper feed/transport
system
Cleaning of sensors and detectors in the paper feed/transport sys-
tem is not always required for every maintenance. In the following
cases, check and clean.
• When a trouble or a jam occurs due to a sensor or a detector.
(Check the jam history.)
Torque limiter check and replacement
Torque limiter check and replacement is not always required for
every maintenance. In the following cases, check and replace.
• When there are some noises.
• When a lot of jams occur frequently. (Check the jam history.)
Parts work
When
Part name
sequence
calling
17
Fusing roller
18
Heating
roller
19
Fusing belt
20
Main
thermistor
21
Paper
guides
22
Gears
23
Pressure
spring
24
Washer
1
Ozone filter
2
Toner
cartridge BK
3
Toner
cartridge C
4
Toner
cartridge M
5
Toner
cartridge Y
6
Waste toner
box
MX-3114N MAINTENANCE 9 – 13
200
300
400
600
800
900
K
K
K
K
K
K
User replacement for every toner empty.
Replaced by the user when full is detected.
Alcohol for cleaning
Be sure to use ethanol for cleaning.
Cleaning of the primary transfer mode detector (CL/BK)
• When replacing the OPC drum, remove the primary transfer unit
and the developing unit, and clean them.
• Blow air to the light emitting section and light receiving section to
remove the attached toner.
• Blow air also when the sensor is wiped and cleaned with waste
cloth.
1000
1200
Remark
K
K
Apply grease to the
shaft section when
replacing. (JEF552) /
Integrated with the
pressure roller as a
maintenance kit.
Replace at every 200K.
Replace as needed.
Integrated with the fuser
belt guide collar as a
maintenance kit. / When
replacing, clean the
fusing belt surface with
alcohol.
Replace at every 200K.
Replace as needed.
Replace as needed.
Replacement reference:
50K

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx-2614nMx-3114n

Table of Contents