Sharp MX-2314N Service Manual page 123

Digital full color multifunctional system
Hide thumbs Also See for MX-2314N:
Table of Contents

Advertisement

7)
Loosen the paper feed tray off-center adjustment screws (2
pcs.) at the center section of the lift plate of the paper feed tray,
and change the gear unit position in the front/rear frame direc-
tion. Repeat the adjustment procedures from 4).
Normally if the adjustment is executed by ADJ 4 (automatic adjust-
ment), there is no need to execute this adjustment.
Only when the manual adjustment is required, execute this adjust-
ment.
In other words, this manual adjustment is executed when a satis-
factory result is not obtained from the automatic adjustment (ADJ
4).
ADJ 16
Scan image magnification ratio
adjustment
(Manual adjustment)
Normally if the adjustment is executed by ADJ 4 (automatic adjust-
ment), there is no need to execute this adjustment.
Only when the manual adjustment is required, execute this adjust-
ment.
In other words, this manual adjustment is executed when a satis-
factory result is not obtained from the automatic adjustment (ADJ
4).
16-A
Scan image magnification ratio adjustment
(main scanning direction) (Manual
adjustment) (Document table mode)
If the default adjustment value of the scan image magnification
ration adjustment (main scanning direction) of SIM 48-1, copy
image quality may be degraded. Therefore, this adjustment must
be executed only when there is a special necessity.
MX-3114N ADJUSTMENTS AND SETTINGS 5 – 74
This adjustment must be performed in the following cases:
* When the copy magnification ratio in the copy image main scan-
ning direction is not properly adjusted.
* When the scanner motor is replaced.
* U2 trouble has occurred.
* When the scanner control PWB is replaced.
* When the EEPROM of the scanner control PWB is replaced.
Before this adjustment, the focus adjustment (CCD unit installing
position adjustment) must have been completed.
1)
Place a scale on the document table as shown in the figure
below.
2)
Enter the SIM 48-1 mode.
3)
Make a normal copy and obtain the copy magnification ratio.
Press [CLOSE] key to shift from the simulation mode to the
copy mode, and make a copy.
4)
Check that the copy magnification ratio is within the specified
range (100  1.0%).
If the copy magnification ratio is within the specified range (100
 1.0%), the adjustment is completed. If the copy magnification
ratio is not within the specified range, perform the following
procedure.
5)
Change the CCD (MAIN) adjustment value of Simulation 48-1.
When the adjustment value is increased, the copy magnifica-
tion ratio is increased.
When the adjustment value is changed by 1, the copy magnifi-
cation ratio is changed by about 0.02%.
Repeat the procedures 3) - 5) until the copy magnification ratio
is within the specified range (100  1.0%).

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx-2614nMx-3114n

Table of Contents