Power factor PF
Accumulate total generator power W
Output percentage with load
For Mains, controller has over and under voltage, over and under frequency, loss of phase, and
phase sequence wrong functions; for generator, controller has over and under voltage, over and
under frequency, over current and over power, reverse power, loss of phase, phase sequence
wrong functions.
Precisely collect parameters about Engine.
Temp. (WT)
Oil Pressure (OP)
Fuel Level (FL)
Speed
Voltage of Battery
Voltage of Charger
Total running accumulation maximum 65535 hours can be recorded.
Start times accumulation
Control protection function: realize automatic start/stop of the diesel gen-set, breaker close/open
(Auto Transfer Switch) control and perfect fault indication and protection functions etc.
With ETS (energize to stop), idle control, pre-heat control and rise/drop speed control functions,
which are all relay outputs.
Parameter setting function: allow users to modify and set parameters and at the same time
parameters can be stored in internal FLASH memory and won't get lost even in case of power
outage; most of them can be adjusted from front panel of the controller and all parameters ca be
adjusted via USB by PC, or via RS485 or ETHERNET port;
Multiple temperature, pressure, fuel level sensor curves can be used and custom sensor curves are
available.
Multiple crank disconnect conditions (speed, oil pressure, generator frequency) are optional.
Wide power supply range DC(8~35)V, suitabel for different starting battery voltage environments.
Event log, real-time clock, scheduled start & stop generator (can be set as start genset once a
day/week/month whether with load or not). Two gensets cycle start function.
Controller can record data up to 5 pieces include mains voltage, mains frequency, generator
voltage, generator frequency, current, temperature, oil pressure, fuel level, speed and etc. one
minute before shutdown fault.
It can be used for pumping unit, moreover, can be indicating instrument as well (only indicate and
no action for alarm and relay).
Maintenance function, maintenance time or maintenance time due can be user-defined (only
warning/trip shutdown/alarm shutdown).
Cycle start two gensets via RS485 or Internet access (running time of both main unit and standby
unit can be user defined)
Waterproof security level IP65 due to rubber seal installed between the controller enclosure and
panel foil.
Controller uses metal fixing clips.
Modular design, pluggable connection terminals and embedded installation way, and compact
structure with easy mounting.
HGM7100N Genset Controller
HGM7100N GENSET CONTROLLER USER MANUAL
° C/° F
kPa/psi/Bar
%(unit)
r/min (RPM)
V (unit)
V (unit)
maximum 65535 times can be recorded
2020-09-10
kWh, kVarh, kVAh (unit)
%
Version1.2
Page 5 of 47