No.
8
Warming Up Time
9
Cooling Time
10
Stop Idle Time
11
ETS Solenoid Hold
12
Wait For Stop Time
13
After Stop Time
Engine
1
Engine Type
2
Flywheel Teeth
Engine
Rated
3
Speed
4
Speed On-load
Speed Signal Loss
5
Delay
Speed Signal Loss
6
Action
Over
Speed
7
Shutdown
Under
Speed
8
Shutdown
Over
Speed
9
Warning
Under
Speed
10
Warning
Battery
Rated
11
Voltage
Battery
High
12
Voltage Warning
Battery Low Voltage
13
Warning
HGM7100N Genset Controller
HGM7100N GENSET CONTROLLER USER MANUAL
Range
Default
(0-3600)s
10
(0-3600)s
10
(0-3600)s
0
(0-3600)s
20
(0-3600)s
0
(0-3600)s
0
(0-39)
0
(1.0-300.0)
118
(0-6000)RPM
1500
(0-100)%
90
(0-3600)s
5
(0-1)
0
(0-200)%
114
(0-200)%
80
(0-200)%
110
(0-200)%
86
(0-60.0)V
24.0
(0-200)%
120
(0-200)%
85
2020-09-10
Description
Warming time before close after genset
entering high speed running.
Radiating time before gen-set stop, after it
unloads.
Idle running time while gen-set stops.
Stop electromagnet's power on time when
gen-set is closing down.
When "ETS Solenoid Hold" is set as 0, it is
the time between gen-set idle delay expired
and stopped completely;
When "ETS Solenoid Hold" is not 0, it is time
between ETS hold delay expired and
stopped.
Time from gen-set stopped to standby.
Default: conventional engine.
It is tooth number of the engine, which is used
for
judging
starter
conditions and inspecting engine speed. For
details, please see the following installation
description.
Provide standards for judging over/under
speed and on-load speed.
The set value is rated speed percentage. The
controller detects it while gen-set preparing to
take the load, if the speed is less than the
on-load speed, gen-set will not enter the
normal operation period.
Time from the speed is detected as 0 to the
action confirmed.
0: Warning; 1: Shutdown
The setting value is the percentage of rated
speed, and delay value can be set.
The set value is the percentage of rated
speed, return value and delay value can be
set.
Provide
standard
over/under voltage.
The set value is the percentage of rated
voltage, return value and delay value can be
set.
Version1.2