Beckhoff AX8000 Series Manual page 41

Multi axis servo system
Hide thumbs Also See for AX8000 Series:
Table of Contents

Advertisement

X01 – voltage input on AX8620
Commissioning
Commissioning of the AX8000 is only possible if the terminal points "Rbin+" and "RB -" are
bridged (delivery state) or an external brake resistor is connected to the terminal points
"R
+" and "R
-".
B
B
Without this measure the AX8000 is stopped with an error message.
Infographic
Terminal
point
PE
L3 / N
L2
L1
X01 – voltage input on AX8640
Infographic
Terminal
point
L3 / N
L2
L1
PE
Multi axis servo system AX8000
Connection
Protective conductor
Phase L3 / N (for 1-
phase power supply)
Phase L2
Phase L1
Connection
Phase L3
Phase L2
Phase L1
Protective conductor
Version: 1.6
Max. wire cross-section
2
6 mm
(AWG 8)
Max. wire cross-section
2
16 mm
(AWG 6)
Electrical installation
Tightening torque
0.5 – 0.6 Nm
(4.4 – 5.3 lbf in)
Tightening torque
1.2 – 1.5 Nm
(10.6 – 13.3 lbf in)