7.3.3

Fusing, CE-compliant

External fuse protection
Fire hazard through short circuit!
The recommended fuses are used for line protection. The servo drives are equipped with integrated self-
protection.
Fuse protection
*)
AC supply (max.)
24 V supply (max.)
*) Mains fuses of operating class "gG (A)" according to IEC60269 or automatic circuit-breakers with
characteristic "C" shall be used.
UL configuration example of a system group:
Please also note the UL configuration example of a system group with components of the
AX8000 multi-axis servo system. All relevant information on the configuration and fuse pro-
tection of the system group can be found in chapter:
"UL configuration example of a system group" [} 12]
Internal fuse protection
Fuse protection
24 V – system voltage / peripherals
Brake resistor (internal)
Multi axis servo system AX8000
CAUTION
AX8620-0000
30 A
NOTE
Fuse
electronic
electronic
Version: 1.6
Electrical installation
AX8640
60 A
20 A
43