Download Print this page

Nokia Alcatel-Lucent OXO Connect Series Installation Manual page 178

Advertisement

Chapter
8
Migration from a PowerCPU EE to a PowerCPU EE C25, or vice-versa, is not supported.
8.14.4.1.1 Prerequisites
To carry out an upgrade to OXO Connect R2.1, you need:
A migration kit for the new CPU (PowerCPU EE or PowerCPU EE C25)
The correct version of OXO Connect R3.x with the associated software licenses
OMC R30.x
LOLA R23.x
8.14.4.1.2 On Site Migration to OXO Connect R3.x
Note:
Migration from a PowerCPU running an OmniPCX Office RCE RCE release to a PowerCPU EE running an OXO
Connect R2.0 (or higher) can only be performed from LOLA.
To migrate the system to OXO Connect R3.x:
From an OXO Connect R2.x:
1. Use the OMC R30.x to save configuration data from the current CPU
2. Use the OMC to download/swap without data saving to OXO Connect R3.x
3. Use the OMC to restore the configuration data previously saved in the current CPU
From an OmniPCX Office RCE R3.1, R4.1, R5.1, R6.1, R7.1:
1. Use the OMC R30.x to save configuration data from the current CPU
2. In OMC off-line, adapt the saved database to OXO Connect R3.x hardware level (change CPU
type, remove CoCPUs)
3. Use LOLA R21.x to save customer data from the current main CPU (select option Migration
mono CPU)
4. Unplug the CPU and the unsupported boards from the system
5. Change the existing hardware for OXO Connect R3.x hardware
6. Plug the new CPU
7. Use LOLA to install the OXO Connect R3.x in the new CPU
8. Use LOLA R23.x to restore the previously saved customer data in the new main CPU
9. Use OMC to restore the previously saved and modified configuration data in the new main CPU
From OmniPCX Office RCE R8.x, R.9.x, R10.1, R10.2:
1. Use the OMC R30.x to save configuration data from the current CPU
2. Use the OMC to download/swap without data saving to OXO Connect R3.x
3. Use the OMC to restore the configuration data previously saved in the current CPU
From OmniPCX Office RCE R10.3:
1. Use the OMC R30.x to save (backup) configuration data from the current CPU
2. Use the OMC to download/swap with data saving to OXO Connect R3.x
8.14.4.2 Remote Migration
Remote migration may be performed when the CPU remains the same (PowerCPU EE). It is also
possible for a migration from OmniPCX Office RCE R10.3 to OXO Connect R2.1.
8.14.4.2.1 Prerequisites
To carry out an upgrade to OXO Connect R3.x, you need:
OMC R30.x
8.14.4.2.2 Remote Migration to OXO Connect R3.x
1. Use the OMC R30.x to save configuration data from the current CPU