The internal switch has three ports:
A LAN port
An internal port
A PC port, to connect a PC to the LAN.
The internal switch privileges VoIP traffic over PC port traffic.
This switch has two waiting queues:
The HPQ (High Priority Queue) to proceed all packets from the terminal
The LPQ (Low Priority Queue) to proceed packets from the PC port
The switch proceeds seven HPQ packets for an LPQ packet.
Exception: packets from the PC port use the HPQ when they are tagged with a DSCP or 802.1p priority
and when the priority value is superior or equal to 4.
8.1.2.1.2.7 Resetting user data
To reset user data:
1. In OMC, go to Users/Base stations List > Details.
2. Click Reset.
The Reset window opens.
3. Select Reset User Data and click OK.
4. In the confirmation window, click Yes.
8.1.2.1.2.8 Rebooting an 8082 My IC Phone set
To reboot a set:
1. In OMC, go to Users/Base stations List > Details.
2. Click Reset button.
The Reset window opens.
3. Select Reboot and click OK.
4. In the confirmation window, click Yes.
8.1.2.1.2.9 Displaying SIP connection current status
This feature allows the display of SIP connection status.
To display SIP connection status:
1. In OMC, go to Users/Base stations List > Details.
2. Read the SIP connection status (under the terminal's physical status).
The following table lists the different displayed status.
table 8.2: SIP connection status display
Displayed Status
Set not connected
SIP registration KO
Set unregistered
8AL91217USAA - Ed. 01 - July 2018 - Installation Manual
Device commissioning
Meaning
SIP phone disconnected from network / No SIP
registration request from the phone
SIP registration request from SIP Phone rejec-
ted by OXO Connect
SIP phone unregistered from OXO Connect