Note:
Due to hardware, there is a limit in the number of channels that you can configure.
You can configure the following numbers of channels:
DECT EUROPE, LATAM, CHINA: 1, 2, 4, 5, 8, 10 channels
DECT US: 1, 2, 4, 5 channels
PWT: 1, 2, 4, 5, 8 channels
8.10.1.9 Initialization
Once the IBS finishes the downloading, the system starts the initialization.
The system synchronizes the signals of the IBSs so that handovers are possible. The system selects
the T0, T2, or CPU main board clock as the source.
Then the system sends the following data:
Fixed part capabilities (Full slot, frequency control, page repetition, setup on dummy, basic A field
setup): value sent = 0x007910
Line length: Short line
Frequency plan (2 bytes)
Some countries have shifted DECT frequencies. In order to be compatible with all frequency bands in
the different countries, 4 types of initialization of frequency plans are available:
Europe, Latin America, The United-States and China.
Channel
Note:
By default, all frequencies used
Value sent to IBS: 0x3FF
0000 0011 1111 1111
8AL91217USAA - Ed. 01 - July 2018 - Installation Manual
Device commissioning
table 8.5: RF Band Europe
0
1
2
3
4
5
6
7
8
9
TX Freq
1897.344
1895.616
1893.888
1892.160
1890.432
1888.704
1886.978
1885.248
1883.520
1881.792
RX Freq
1898.206
1896.480
1894.752
1893.024
1891.296
1889.566
1887.840
1886.112
1884.384
1882.656