Chapter Six: Programming the Controller
690 ms
Tt-T5
=
33
ms
---1L-.___
W_A_K_E_U_P_ _.....
H T11T21T31T
4IT5[~~]
X=45ms
9SP"
45 ms
(6 tone onl y)
Fig.
6-3. 5/6
Tone Sequential Timing
Tone Panel
The frequency of each tone can be set with Programming com­
mands. Tone #1 can be selected for encode or decode. Tones
Frequencies
#2-8 are decode only.
"'SIOOx
Tone #1 ENCODE or DECODE
Tone
(x
=
1 Encode; x
=
0 Decode)
"'SIOT FF
Tone #T Frequency
Tone
(x
==
1-8; FF from table below)
Note
The controller must be "Reset" for Tone Panel commands to take
effect. Enter (COP prefix) 18 after locking the controller.
CTCSS FREQUENCIES
01
67.0
11
-
21
136.5
31
192.8
02
71.9
12
100.0
22
141.3
32
203.5
03
74.4
13
103.5
23
146.2
33
210.7
04
77.0
14
107.2
24
151.4
34
218.1
05
79.7
15
110.9
25
156.7
35
225.7
06
82.5
16
114.8
26
162.2
36
233.6
07
85.4
17
118.8
27
167.9
37
241.8
08
88.5
18
123.0
28
173.8
38
250.3
09
91.5
19
127.3
29
179.9
10
94.8
20
131.8
30
186.2
Fig. 6-4. CTCSS Frequencies