Chapter Six: Programming the Controller
*1020
*1120
Phone Answer
PH
16
*1021
*1121
Phone Hangup
HG
8
*1022
*1122
Alarm
AL
8
*1023
*1123
Bulletin Board #1
Bl
32
*1024
*1124
Bulletin Board #2
B2
32
*1125
Patch Dialing Prefix
OX
6
(Each message can be either Morse or speech, but not both
there is only one storage location per message.)
Hints
Many vocabulary words occupy only one character slot. How
ever, words beginningwith *1, *2, *3, *4, or *9 occupy
two character slots.
The Patch Dialing PrefIx is not a message per se, but is the tele
phone dialing string that can precede all phone patches.
For example, if the controller is connected to a PBX, it
can be necessary to dial "9 pause" before all calls. Load
speech "9 (pause)" into this message.
An external tape player can be addressed from any program
mable message by selecting the message with the com
mand "* 13.xx" and loading the message with the Morse
letter "X." For example, to have Bulletin Board #2
address the external tape player, enter the command
"*1324" and load the character "X" (92), then write the
message into memory. See Chapter 8 for details of inter
facing the external tape player.
Digital Voice Recorder tracks can be addressed from any
programmable message. For example: To load OVR
track #20 into Pending ID 1, enter * 1303. The controller
responds with, "Pl." Using the vocabulary codes, enter
P20 with 710200. Enter *0 to store the message in mem
ory. See Chapter 8 and the OVR manual for details.
Tone
Parc~_meters
The Morse code speed and pitch and the Cover Tone pitch can be
changed using these commands; speed is entered directly in
words per minute and pitch is entered in Hertz. The Cover Tone
can be made inaudible if desired by setting a very low pitch. .
*2000(speed)
Morse Code Speed
speed
=
12 - 30 wpm
*2010(pitch)
Morse Code Pitch
pitch
=
1 - 3000 Hz
*2020(pitch)
Cover Tone Pitch
pitch
=
1 - 3000 Hz
Example
Set the Cover Tone Pitch to 440 Hz.
Unlock the controller. Enter "*2020440" (or "*2020440#"
over the phone or from the front panel).
Controller responds with Forced CW ID message at the selected
pitch.
56 • RC-96 REPEATER CONTROLLER OWNER'S MANUAL