Chemical Editing Screen - USC PS10 Operator's Manual

Pump stand with u-treat lite
Table of Contents

Advertisement

1
2
3
4
1. Selection List Button: Selecting this button opens a display list popup which
allows for the selection of what chemical profile we would like to edit.
2. Copy Button: Selecting this button copies all fields except the name of the
currently selected profile. This is used with the Paste button to select another entry
and paste contents into another profile.
3. Paste Button: Selecting this button pastes all fields except the name of the current
selected profile. This is used with the copy button to paste copied contents into the
currently selected profile.
4. Save Button: Selecting this button saves the currently selected profile.
5. Name Field: This field allows the operator to assign a name to the chemical they
are operating. The system sorts chemicals by name.
6. Chem Calb Factor: This field allows the operator to enter a calibration factor for
the chemical profile. This factor adjust the flow meter reading when using a flow
meter style pump. If using a LIW pump this factor adjust the initial speed of the
pump. The default for this field is 1.0 and can be adjusted using the calibration
popup on the HOA page.
7. Chem Calb Factor Adj: This field is only visible when the pump is configured as a
LIW pump. Selecting this field toggles between Auto L-I-W or Manual. When in
Auto L-I-W the LIW pump will automatically adjust the calibration factor to adjust its
starting speed. Every run the pump will evaluate its flow rate after it collects data
form the scale and adjust its starting speed to more accurately hit the desired rate.
In manual mode, the operator may enter his own calibration factor to set his
starting speed at.
Page 38
PUMP STANDS PS10

Chemical Editing Screen

5
6
7
8
9