Tank Fill Settings - Raven RCM-Sprayer Hawkeye 2 Calibration And Operation Manual

Hide thumbs Also See for RCM-Sprayer Hawkeye 2:
Table of Contents

Advertisement

FLOW METER LOW LIMIT
The minimum flow rate which the flow meter can read accurately. When the flow rate is below this setting, the flow
will be calculated based off the pressure and tip size.
NOTE:
Refer to the flow meter manufacturer's specifications when setting the low limit.
TANK FILL FLOW METER CALIBRATION
The fill system flow meter calibration value and units may be found on the tag attached to the flow meter installed
in the fill system plumbing.
NOTE:
Be sure to select the appropriate units for the flow meter calibration to ensure proper calibration of
the tank fill system.
TANK FILL FLOW METER PULSE/UNITS
NOTE:
This feature is not available with injection product control channels.
Select the units for the flow meter from this drop-down list. The pulses/units is the number of pulses which the
flow meter will generate for a given amount of product measured by the flow meter. The fill meter calibration, or
meter cal, value and units may be found on the tag attached to the flow meter installed in the tank fill system.
For example, a flow meter calibration value of 710 and a Pulse/Units value of 10 L indicates that 10 liters of product
is measured through the flow meter for every 710 pulses of the flow meter. Be sure to select the appropriate units
for the flow meter calibration to ensure proper calibration of the tank fill system.
NOTE:
Raven flow meters use a meter cal in pulses per 10 gallons [37.9 L].
Copy the information from the tag for future reference as tags may fade or be lost during operation.

TANK FILL SETTINGS

To adjust tank fill system settings:
UT Menu
RCM - Sprayer Menu
1. Open the UT Menu and select the RCM - Sprayer Menu button.
2. Select the Tools Menu softkey along the right side of the display.
3. Select the System Settings tab along the top of the display.
4. Select the Tank Fill Settings button on the System Settings page. The following settings and options are
available to configure tank settings for the main product or injection products.
TANK CAPACITY
Enter the maximum tank capacity. The tank level indicator on the home screen uses the
maximum tank capacity and current tank level values to display the level of product
remaining in the tank.
NOTE:
Tank capacity value cannot be changed during an active job.
System Setup: System Settings Tab
Tools Menu
System
Settings
SYSTEM SETUP
Tank Fill
Settings
27