RFM 60 - 1.5 gpm (5.7 L/min)
RFM 100 - 3 gpm (11.4 L/min)
RFM 200 - 15 gpm (56.8 L/min)
4. If a Tank Fill/Level Sensor is installed, use the drop-down field to select the sensor type if available. If a tank fill
flow meter is selected, enter the meter cal and units for the sensor before proceeding with the calibration.
5. Select the Next button to continue to the Tank Fill Setup page.
TANK FILL SETUP
1. Touch the Tank Capacity field and enter the volume of product in a full tank.
2. Touch the Current Tank Level field and enter the current product volume in the tank.
3. Touch the Low Tank Level field and enter the volume at which the operator should be alerted to a low tank
condition. Enable the Alarm option to allow the system to activate an audible alarm when the Low Tank Level is
reached during field applications.
4. Touch the Max Tank Fill PWM field and enter the maximum duty cycle for the pump to refill the product tank.
5. Touch the Next button to continue to the Rates Setup page.
NOTE:
Additional tank fill setup pages will be displayed for any additional products detected on the system.
System Calibration: Initial Start Up and Calibration Wizard
SYSTEM CALIBRATION
15