Raven RCM-Sprayer Hawkeye 2 Calibration And Operation Manual page 22

Hide thumbs Also See for RCM-Sprayer Hawkeye 2:
Table of Contents

Advertisement

CHAPTER 3
PROFILE NAME AND MACHINE TYPE
1. Touch the Profile Name field and enter a name for the machine or equipment configuration being set up.
2. Touch the Machine Type drop-down field and select the option that best matches type of machine or
equipment to be configured.
3. Select the Next button to continue to the NCV2 Setup page.
SYSTEMS WITH SIDEKICK PRO ICD INJECTION PUMPS
1. Locate the Sidekick Pro ICD ECU serial number. The serial number is typically located on the front or top of the
direct injection pump.
2. Assign the desired Sidekick Pro ICD ECU to the desired product channel.
3. Press the Next softkey.
TIP AND NCV2 SETUP, SPACING, AND TIP SIZE
When setting up an RCM - Sprayer systems without Hawkeye® 2 NCVs, or if the Skip NCV Setup option is
selected:
1. Enter the "Bypass Tip Spacing" and "Bypass Tip Size."
NOTE:
If no spray tips are installed, or if the installed tip size is not available in the drop down menu, select
NA as the tip size.
When setting up a Hawkeye® 2 NCV control system:
1. Verify that the actual number of Hawkeye® 2 NCVs on the system matches the value shown in the Total NCV2s
field detected by the ECU.
NOTE:
Touch the Redetect NCV2s button to allow the system to detect NCV2s connected to the nozzle bus.
2. Verify the actual number of NCV2s connected to the left boom (center of the boom to the tip of the left boom)
circuit matches the value shown in the Left NCV2 Count field detected by the ECU.
NOTE:
If the total number of NCV2s, or the left NCV2 count, displayed does not match the actual number of
nozzle control valves connected to the system, refer to Chapter 9, Troubleshooting, for assistance with
the
Hawkeye® 2
To bypass nozzle control valve configuration and operate the system without the Hawkeye® 2 NCVs,
press the Skip NCV2 Setup button. If Nozzle Control Valves are installed on the machine, the NCV2s
will remain closed and must be manually bypassed at the boom by opening a secondary flow outlet
or removed from the machine to apply product. The system will then operate as a conventional
sprayer with the RCM - Sprayer ECU.
3. Select the NCV2 Spacing field and enter the distance between nozzle bodies in the units displayed. A nozzle
body spacing value must be entered to continue with the calibration.
4. Select the NCV2 and Bypass Tip Size fields and select the orifice size of the tips currently installed on the nozzle
bodies.
NCV is the tip connected to the Hawkeye® 2 NCV.
The Bypass Tip is for secondary tips on each nozzle body.
NOTE:
If no tips are installed, or the installed tip size is not available in the drop down menu, select NA as the
Tip Size.
5. Select the Next button to proceed to the NCV2 Indexing prompt.
12
nozzle control valve circuit.
RCM - Sprayer and Hawkeye® 2 Calibration and Operation Manual

Advertisement

Table of Contents
loading

Table of Contents