Rcm - Sprayer Features; Operation Modes - Raven RCM-Sprayer Hawkeye 2 Calibration And Operation Manual

Hide thumbs Also See for RCM-Sprayer Hawkeye 2:
Table of Contents

Advertisement

CHAPTER 2

RCM - SPRAYER FEATURES

OPERATION MODES

The RCM - Sprayer with Hawkeye® 2 control system can be configured in several different modes to fit the
application.
Operation Modes and Compatible Features
TABLE 1.
Direct
Injection
Wireless
Diagnostics
Flow Control
Pressure
Control
Turn
Compensation
Virtual
Sections
Hawkeye HD
Individual
Nozzle Control
Bypass (Conventional) Mode. The RCM - Sprayer with Hawkeye® 2 mode will control to a target flow, but the
nozzle control valves on the system are disabled. A secondary flow outlet must be made available at each tip.
NOTE:
If NCV2s are not detected, the RCM - Sprayer system will automatically configure in Bypass mode.
Bypass mode may also be selected to revert a system with Hawkeye® 2 NCVs to conventional spray
control.
Only select bypass mode if the nozzle bodies on the implement are set to bypass the
NCVs during operation.
Standard Mode. The RCM - Sprayer with Hawkeye® 2 mode will control to a target flow rate and maintain a
constant target pressure.
Variable Pressure (VP) Mode. This RCM - Sprayer with Hawkeye® 2 mode will control to a target flow rate and
target NCV2 duty cycle by varying the pressure range. This is useful for scenarios where maintaining a constant
target pressure is not a priority such as liquid fertilizer application or where droplet size can be maintained over
a wide pressure range.
High Flow Mode. This RCM - Sprayer with Hawkeye® 2 mode allows both a conventional nozzle and a
Hawkeye® 2 NCV to run simultaneously to achieve higher flow rates.
On/Off Mode. The RCM - Sprayer with Hawkeye® 2 System will hold the NCV2s 100% open during application or
fully closed when not applying. This mode can be used with air induction tips and stream bars.
6
Conventional
Standard
/Bypass
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
No
Yes
No
Yes
RCM - Sprayer and Hawkeye® 2 Calibration and Operation Manual
Modes of Operation
Variable
Pressure (VP)
Yes
Yes
Yes
No
Yes
Yes
Yes
High
On/Off
Flow
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
No
Yes
No
Yes
Hawkeye® 2