Fitting The Busbar Connectors - ABB ACS6080 User Manual

System drives
Hide thumbs Also See for ACS6080:
Table of Contents

Advertisement

10. Start the drive according to the established procedures.
9.4.9.2

Fitting the busbar connectors

1. Shut down the drive according to the established procedures.
2. Fit the busbar connectors in the sequence shown in Fig. 9-21.
3. Remove the grounding sets.
4. Check that the LEDs are lit.
5. Check that tools and foreign objects are not left inside the cabinets.
6. Close and lock the doors.
7. Check that the power operating mode (POM) of the drive corresponds
to the busbar connectors fitted.
8. Start the drive according to the established procedures.
3BHS842007 E01 REV C
1
3
Figure 9-21 Fitting sequence for busbar connectors
ACS6080 USER MANUAL
09 PREVENTIVE AND CORRECTIVE MAINTENANCE
2
4
212/238

Hide quick links: