(1) Outer cable sheath
(2) Grommet
(3) EMC sleeve
(4) Plate
6.8.5

Routing cables in a WCU

For the available cable routing options in WCU800 and WCU1400, such as
top entry and bottom entry, see "Appendix C – Mechanical drawings".
6.8.6

Routing cables in a COU cabinet

The serial communications and encoder cables are connected inside
a COU.
Top and bottom cable entries are covered with blanking plates.
Materials for cable fitting, EMC requirements and sealing are
not supplied.
3BHS842007 E01 REV C
1
2
3
Figure 6-29 Preparing control cables for EMC plates
ACS6080 USER MANUAL
06 ELECTRICAL INSTALLATION
5
6
6
6
(5) Cable sheath removed to expose
cable shield
(6) Conductor screen extension to
connect to PE terminal
4