5.7.1
DC busbars
The DC busbars can be accessed from the back and the top of the cabinet.
If necessary, you can remove the top plates and the rear walls.
Note: If you need to remove the air-to-air heat exchangers to access the
top plates, see "5.8.2 Removing air-to-air heat exchangers" on page 111.
The following DC busbar configurations depend on the configuration of
the drive:
• DC busbar configuration 1 (Fig. 5-4)
• DC busbar configuration 2 (A in Fig. 5-5
• DC busbar configuration 3 (B in Fig. 5-5)
• DC busbar configuration 4 (C in Fig. 5-5)
Item
(1) Connecting plate
(2) Hex-head bolt
(3) Hex-head nut
(4) Conical spring
washer
(5) Busbar with positive potential
(6) Busbar with neutral potential
(7) Busbar with negative potential
(8) Front of cabinet
3BHS842007 E01 REV C
2
4
1
4
3
8
5
6
NP
7
Figure 5-4 Top view of DC busbar configuration 1
Quantity
3
6
6
6
ACS6080 USER MANUAL
Technical
Identification
parameters
Flex
3BHB010246R0001/
R0051
M12 x 35-A2
NB 312350P8118
M12-A2-70,
HZN 452198P1022
coated
13 x 29 x 3
HAQN400344P0111
05 MECHANICAL INSTALLATION
3
4
1
4
2
98/238