Converting 3-Phase To 1-Phase Operation - Champion DH6000T-VHR Installation Manual

Table of Contents

Advertisement

Installation
Converting 3 Phase to 1-Phase Operation
Convert
jumper wire on the input power block and rewiring
the wash tank and booster tank heaters.
A jumper wire, jumper bars and a new data
plate are stowed inside the control cabinet.
TO CONVERT:
Install Main Terminal Block Jumper Wire
1. Disconnect all power to the machine.
2. Remove front panel to access the power terminal block.
3. Connect jumper wire (shipped inside control cabinet)
between L2 and L3 on output side of block.
4. Connect power on L1 and L2 of the terminal block.
Rewire Wash Tank Heater Element for 1PH
1. Remove the paper insulator and jumper
bars from the heater terminals.
2. Additional short jumper bars are
stowed with the new data plate.
3. Reposition the jumper bars for 1PH as shown.
4. Reconnect the heater wires as shown.
5. Reinstall the paper insulator.
Rewire Booster Heater Element for 1PH
1. Remove the booster heater element cover.
2. Remove the paper insulator and
jumper bars from the heater terminals.
3. Install the jumper bars for 1PH as shown.
4. Additional short jumper bars are stowed
with the new data plate.
5. Connect the wires to the terminals as shown.
6. Reinstall the paper insulator and the
booster heater element cover.
10
3 Phase to 1 Phase by installing of a
Fig. 15
1 Phase 208-240/60/1
LINE IN
L1
L2
GRD
L1
L2
JUMPER
1PH
L1
L3
1PH
L3
L1
L2
L3
L2