Champion DH6000T-VHR Installation Manual page 31

Table of Contents

Advertisement

Installation
DET R /A
Rinse-aid Cycle -
Sets the time the rinse-aid pump
runs during final rinse.
Factory Default = 5 sec.
Manual Priming (Password Free)
The Detergent Prime (DET PRIME) and
Rinse aid Prime (RA PRIME)
do not require password access.
Press the desired button until
chemical fills the lines and release.
Programming
D E T ER G ENT
CYCLE TIMES
CONCENTRATION
RINSE AID
5
DET PRIME
RA PRIME
BACK
15