Electrical Connection - Single and Three Phase
3 Phase Power Connection
208-240/480V/60/3
L1
L2
L3
Fig. 12
Single to Two Point Power Connection Conversion
1.
Machine wiring can be converted from a single to a two point input power connection
by installing a field conversion kit, P/N 901168.
2.
New electrical connection data plates must be applied in front of the input terminal
blocks.
3.
Refer to Appendix B at the end of this manual for conversion instructions.
L1
L2
L3
L1
L2
L3
WARNING:
There may be more than one power source connected to the
machine. Make sure all power sources are disconnected,
locked and tagged out before working on the machine.
L1
L2
L3
GND
2-Point Machine Connection Data Plate
L1
Mod: DH6000T
For supply connection, use copper connectors in accordance
L2
with local electrical code. Rated Minimum 90°C (194°F).
Overcurrent Protection Device: Time Delay or Inverse Time
Circuit Breaker
L3
Minium Supply Conductor Ampacity
Maximum Supply Overcurrent
Protection Device
Volt: 208-240
GND
2-Point Booster Connection Data Plate
Mod: DH6000T
L1
For supply connection, use copper connectors in accordance
with local electrical code. Rated Minimum 90°C (194°F).
Overcurrent Protection Device: Time Delay or Inverse Time
L2
Circuit Breaker
Minium Supply Conductor Ampacity
Maximum Supply Overcurrent
L3
Protection Device
Volt: 208-240
GND
1 Phase Power Connection
208-240V/60/1
L1
L2
NOT
USED
GND
Fig. 13
Series: VHR
50/50
AMPS
50/50
AMPS
Ph: 3
Hz: 60
Amp: 38-34
Series: VHR
50/50
AMPS
50/50
AMPS
Ph: 3
Hz: 60
Amp: 39-34
Fig. 14
Installation
L1
L2
NOT
USED
9