APPENDIX B: 1-Point to 2-Point Electrical Connection Conversion, Kit P/N 901168
10. Connect the booster wires to
the booster terminal block (Fig.7).
11. Cover the existing 1-Point
machine connection data
plate with 2-Point Machine
connection data plate from
the kit. Install the 2-Point
booster data plate adjacent
to the booster terminal block
(Fig. 7 and Fig. 8).
12. Restore power and check the
operation of the machine.
13. Re-install panels.
14. Conversion is complete.
L1
L1
Mod: DH6000T
For supply connection, use copper connectors in accordance
with local electrical code. Rated Minimum 90°C (194°F).
L2
L2
Overcurrent Protection Device: Time Delay or Inverse Time
Circuit Breaker
Minium Supply Conductor Ampacity
L3
L3
Maximum Supply Overcurrent
Protection Device
Volt: 208-240
GND
L1
L1
Mod: DH6000T
For supply connection, use copper connectors in accordance
with local electrical code. Rated Minimum 90°C (194°F).
L2
L2
Overcurrent Protection Device: Time Delay or Inverse Time
Circuit Breaker
Minium Supply Conductor Ampacity
L3
L3
Maximum Supply Overcurrent
Protection Device
Volt: 208-240
GND
Fig. 7
BOOSTER
Fig. 8
2-Point Machine Connection Data Plate
Series: VHR
50/50
AMPS
50/50
AMPS
Ph: 3
Hz: 60
Amp: 38-34
2-Point Booster Connection Data Plate
Series: VHR
50/50
50/50
AMPS
Ph: 3
Hz: 60
Amp: 38-34
MACHINE
AMPS
29