Installation
Shortening a Chemical Pick-up Hose Supplied by Others
1. Remove the left-side panel to access the
detergent and rinse-aid chemical pumps (Fig. 1).
2. The chemical tubes enter from the rear through
grommets (Fig. 2).
Fig. 2
3. Remove the existing cable-ties. (Fig. 3).
4. Shorten hoses and re-install the hose
barb fittings (Fig. 4).
Fig. 4
5. Make sure all cable-ties are in place and secure
Fig. 5).
6. Procedure Complete.
P/N 115858 Rev. A
20
Fig. 1
Fig. 3
Fig. 5