APPENDIX C: Manual Valve Operation
Manually Operating the Drain Valve
1
Remove four 2.5mm coil retaining allen
3
Using pliers, turn the valve body key to
the vertical position to open valve.
30
•
To manually operate the new valve, four 2.5mm socket
allen screws must be removed, the valve coil removed,
and the valve globe rotated with pliers.
•
The valve coil has an indicator
line showing valve position.
Ensure valve is reassembled in
the same position.
screws.
2
Remove the coil from the valve body.
Reassemble in reverse order.