5.2 Volume Control?

The Volume Control function applies to both the buzzer and the internal sounder.
5.2.1 Area Entry Tone Volume
0=Completely Silent, 1=Silent, but beeps when the system is armed. 2-7 Internal Siren
5.2.2 Area Exit Tone Volume
0=Completely Silent, 1=Silent, but beeps when the system is armed. 2-7 Internal Siren
5.2.3 Alarm Volume
0=Completely Silent, 1=Silent, but beeps when the system is armed. 2-7 Internal Siren
5.2.4 Fire Alarm Volume
0=Completely Silent, 1=Silent, but beeps when the system is armed. 2-7 Internal Siren
5.2.5 Technical Alarm Volume
0=Completely Silent, 1=Silent, but beeps when the system is armed. 2-7 Internal Siren
5.2.6 24 Hour Alarm Volume
0=Completely Silent, 1=Silent, but beeps when the system is armed. 2-7 Internal Siren
5.2.7 Chime Volume
0=Completely Silent, 1=Silent, but beeps when the system is armed. 2-7 Internal Siren
5.2.8 Silent Technical Alert
If enabled, any technical alert sounds (such as mains fail, line fail etc.) will be silent.
NOTE: If the Exit time has started from an Arm Device programmed in multiple areas, or Entry time
started from a door programmed into multiple areas, the HIGHER relevant level will apply.
5.2.9 Disable Call Fault
If enabled, all call faults will not be shown on the display, but they will appear in the log.

5.3 System Configuration - Options?

In the system options there are a number of options available to further tailor the operation of the
system as to the project needs. The system options are described in the table below:
System
Description
Options
Arm Fail =
If 'Yes' = Graduated alarm will be generated when the 'Arm Fail' timer expires (see
Alarm
Program Timers), if an exit procedure is still incomplete the arm fail output will trigger
too. If 'No' = Exit time will continue until the Exit door is closed. It will come back into
disarmed mode at the end of the 'Arm Fail Warning' time if programmed.
Do Battery
If 'Yes' the system will perform a full load test of the battery at 7.00am each day.
Load Test
Arm
Used to show to user outside on the bell that the system has been armed. Will activate
Acknowledge
for 5sec such an indication. You can set this option to: Strobe Flash; Bell Squawk; or
Both. NOTE: Use with care, in view of potential security risk. Since the keyfob can show
this status too we recommend using the keyfob instead.
Disarm
Used to show to user outside on the bell that the system has been disarmed. Will
Acknowledge
activate for 5sec such an indication. You can set this option to: Strobe Flash; Bell
Squawk; or Both. NOTE: Use with care, in view of potential security risk. Since the
keyfob can show this status too we recommend using the keyfob instead.
Bypass On
If 'Yes' the zone/input that generates an alarm when the bell time expires will be
Re-Arm
bypassed. If the zones/inputs are closed then they will automatically become active
again.
Forced Arm
If 'Yes' when arming with user code or auto arm the panel will arm even if an zone/input
is open at the time -and bypass them (bypass attribute must be enabled on each
zone/input).
Tag Only
If 'Yes' the system prevents a user code being entered during the Entry Time, but allows
Disarm
the system to be silenced once in alarm. A tag will disarm and reset the system.
Quick Arm
If 'Yes' allows a user to arm the system by pressing the t key and for the area to arm.
Invert Digi
If 'YES': 'Positive Removed'. If 'NO': 'Positive Applied'. (Default is 'YES'). Any output switches from 5
O/Ps
to 0 volts; if set to YES, they switch to 0 to 5 volts
PCX 46 Programming Reference
Page: 20