4.3 Technical Specification

4.3.1 Main Control Panel

ZONES
Zone Loop Current
DEOL Zone Activation Resistance
NC Zone Activation Resistance
Doubled Zone Activation Resistance
Both Zones Normal >2kΩ to <6kΩ
Both Zones Activated >11kΩ to <35kΩ
Zone n Activated >8kΩ to <11kΩ
Zone n+16 Activated >6kΩ to <8kΩ
Zone Doubled: Tamper Activated <2kΩ or >35kΩ
Zone Response Time
Standard Zones 300ms
Only Zone 1 Fast 30ms
Zone Protection (832/832+ only)
DIGITAL COMMUNICATOR
Telephone Line Monitoring
Telephone Connection
Digital Communicator
Lightning Protection
BATTERY
Type
Battery Charge
Max Battery Charge Current
Plastic Case 350mA
Metal Case (832+) 800mA
Battery Charge Method
RINS918-6
0.54mA – Max.
Short Circuit <800Ω
Normal >800Ω to <6kΩ
Activated >6kΩ to <36kΩ
Open Circuit >36kΩ
Normal <4kΩ
Activated >4kΩ
Fast Zones 100ms
18V Varister
Yes
Allows other tel. on the line
Analogue Line
6.75kV / 125A
12V Lead acid rechargeable
Min 6V
The Matrix panel monitors the
voltage of the battery and
commences charging when the
battery reaches 12.8V ± 5%
and disables charging when it
reaches 13.6V ± 5%
Matrix 424, 832, 832+ Installation Manual
MAX. NUMBER
PROGRAMMABLE OUTPUTS (PGM)
PGM 1
PGM 2
Matrix 424/832 Open collector, 12V@200mA
Matrix 832+ Relay contacts, 30V@3A
PGM 3
PGM 4*
*NOTE: PGM 4 is designed for triggering ONLY.
PCB POWER SUPPLY
Power Input
Transformer Rating
Plastic Case 21VA
Metal Case (832+) 44VA
EN50131-6 Type
Voltage Output
Voltage Range
Ripple
Panel Current Requirement
Constant Current Output
Plastic Case 600mA
Metal Case (832+) 1.1A
Total Current Output
Plastic Case 900mA (for 15mins)
Metal Case (832+) 1.8A (for 15mins)
PCB FUSES
AC Fuse
Aux Fuse
Aux1 (Bell) Fuse (424 - N/A)
Keypad Fuse (832+ only)
Battery Fuse
Mains Fuse
MECHANICAL
Dimensions
Plastic Case 340 x 280 x 94.5 mm
Metal Case (832+) 389.5 x 314.5 x 96.2 mm
Security Grade 2 - Metal (832+), N/A - Plastic
Environmental Class 2 - Metal (832+), N/A - Plastic
TEMPERATURE
4
4
4
2
2
1
1
Relay contacts, 30V@3A
Open collector, 12V@200mA
Open collector, 12V@10mA
17Vac
A
13.6Vdc@1A regulated
Max. 13.8V Min. 10.5V
1% Max.
200mA
Quick blow 2A – F2L
Quick blow 1A – F1L
Quick blow 1A – F1L
Quick blow 1A – F1L
Slow blow 5A – T5H