Program Zones (Inputs) - Pyronix PCX 46 App Programming Reference Manual

Table of Contents

Advertisement

5.1 Program Zones (Inputs)?

By default, all zones/inputs are set to 'unused'. Before programming, identify zone/input type required:
Zone/Input
No
Type
0
Unused
1
Fire
2
Gas
3
PA
#
4
Silent PA
#
5
Tamper
6
Instant
7
Entry Delay1
8
Follow
$
11
Push To Arm
12
Switcher
13
24 Hour
PCX 46 Programming Reference
Operation
Zone/Input is disabled.
Active at all times. Audible Response: Differentiated Internal sound. Pulsed
external sound.
Communicator: 'Fire' signal
Active at all times. Audible Response: Full external + Internal sound.
Communicator: 'Gas' signal
Active at all times. Audible Response: Differentiated Internal sound. Full
external sound.
Communicator: 'Personal Attack' and 'Zone/Input PA' signals
Active at all times. Audible Response: None
Communicator: 'Personal Attack' and 'Zone/Input PA' signals
When disarmed: Audible Response: Internal only.
Communicator: 'Tamper' signal.
When armed: Audible Response: Full external + Internal sound.
Communicator: 'Tamper' signal.
Active when armed: Audible Response: Full external + Internal sound.
Communicator: 'Burglary' signal
#$
Active when armed: Initiates entry timer 1 when door open. If system not
disarmed before entry time expires then:
Audible Response: Full External + Internal sound.
Communicator: 'Burglary' signal
NOTE: See type 43 for Entry Delay2
Active when armed, except during entry time. (Acts as an instant zone/input
if an Entry Delay zone/input hasn't been activated beforehand)
Audible Response: Full external + Internal sound.
Communicator: 'Burglary' signals.
Active during exit time, to complete arming procedure. No audible or
communicator response. Panel will communicate a final armed event once
the Push to Arm button has been pressed.
NOTE: May be used to act as 'doorbell' by use of 'chime' zone attribute.
Example: Wire the Door Bell button to the zone/input. Enable "Push to Arm"
option from "EXIT MODES", add a "Push to Arm" zone/input type to the
zone/input and enable the "Chime" attribute for it.
Enter user code, the panel starts arming. Exit the building and close the
door. Press the Bell button. The system will arm. If pressing the Bell button
while the panel is in any other condition the Chime will sound.
Active at all times in armed and disarmed modes. No audible or
communication alarms will be created.
When activated it can trigger associated output for switching external
equipment. If the "Special Log" attribute is enabled for this zone/input an
SMS message will be sent each time the zone/input is activated.
Example:
This kind of zone/input type can be used to control CCTV. The concept is
that when a switcher zone/input type is activated, there is an output
associated with it following that zone/input (the most used solution is the
use of output type – 0035). The switcher zone/input is connected to a
detector located next to a CCTV camera and the output is connected to a
video recording / transmitting equipment.
If the detector is activated in armed or disarmed mode then the recording or
transmission will start.
When armed: Audible Response: Full External + Internal sound;
Communicator: '24hr Alarm' signal.
When disarmed: Audible Response: Full External + Internal sound;
Communicator: '24hr Alarm' signal.
Page: 8