Quartz Clock
If set to 'YES' then the clock will run from the panel processor, or if 'NO' then the clock will run from
the mains frequency.
Keypad PA
Pressing the dedicated PA button or a combination of 1 and 7 keys will produce a PA.
Key
There are several options for this feature: Disabled=Inactive; Silent+Digi=Silent PA
(signalling only); Bells Only=Bells Only (No signalling); Bell+Signal=Signalling and Bells.
Tag
Used in conjunction with "Door Control" option in Reader setting.
Disarm+Door
If set to 'No' – readers will disarm system but not control doors.
If set to 'Yes' the readers control the arming/disarming and doors as long as the reader
has been programmed in the reader options.
Keypad Fire
If enabled the fire alarm button on the keypad will be enabled.
Key
Arm with
If 'Yes' the panel will arm the system if there is a wireless supervision fault. The keypad
Supervision
will flag up a wireless supervision fault but allow the user to arm the system.
Fault
If "No" will not be possible to arm the system with a supervision fault. The keypad will
flag up the fault and the arming procedure will be stopped.
Keyfob on
If 'Yes' allows use of the wireless keyfob to disarm the system only when the Entry Door
Entry
has been opened and entry time has started.
Download if
If enabled, downloading from the InSite software to the panel is possible regardless of
Armed
whether the system is armed or not. If disabled, downloading will only be possible when
the system is disarmed.
6 Digit Codes
All codes can be 4 - 6 digits. If this option is enabled, all codes must be 6 digits.
Time Prompt
When this option is set to 'Yes' the system will prompt you to update the time if time
information has not been received from the server and the panel has been completely
powered down (mains & battery) -and subsequently lost the current time and date.
5.1 System Configuration – System Displays
Please see page 4 for the 'Text Programming' section as this function involves programming different
text for the
PCX 46 App
System
Description
Displays
Area Texts
You may choose how you want each area to be displayed, i.e. "Area A" may be used to
fully arm a house therefore you may want to call it "Full House Arm" for example. You
can have a maximum of 16 characters on the display.
Banner Text
The top display text is shown on the keypad in disarmed mode.
Display If
If programmed as 'yes' then the system will display on the keypads when the system is
Armed
armed.
Display
If programmed as 'yes' then the system will display on the keypads any alarms without
Alarms
requiring user to enter their code or tag.
Ready LED ON
If programmed as 'enabled', the 'OK' LED will illuminate whilst the panel is disarmed
and when all the zones/inputs in the areas (that the keypad controls) are closed.
Display PAs
If programmed as 'yes' then the system will display on the keypads any PA alarms
without requiring the user to enter their code or tag.
Display Silent
If programmed as 'yes' then the system will display on the keypads any silent PA
PAs
alarms without requiring the user to enter their code or tag.
Display Zones
If programmed as 'enabled', any zone/inputs activated in disarmed mode will be
displayed.
Disarm LED
If programmed as 'enabled', the disarm LED (green) will illuminate continuously whilst
ON
the system is in the disarmed state.
PCX 46 Programming Reference
system.