Change Codes - Pyronix PCX 46 App Programming Reference Manual

Table of Contents

Advertisement

WLs
This is the time window before a supervision fault will be signalled. For
Supervision
example: if the time is set for 2 hours, then any device that doesn't
Time
communicate with the
supervision fault. Must be programmed to 2 hours or less for compliance
to EN 50131.
WLs
This is the time window that if a wireless device had its signal 'blocked' a
Jamming
fault would display. For example, if the time is set for 30 seconds, then if
Time
a wireless device is 'jammed' longer than 30 seconds a fault will be
displayed.
Must be set to 30 seconds or less (but not zero) for compliance to EN
50131.
Service
This is a timer that can be programmed in days, and will display a
Timer
message to the user warning that a service is due. An engineer code will
clear the message.

5.1 Change Codes?

All codes may be 4, 5, or 6 digits long and also can be assigned as proximity tags and keyfobs. 100 user
codes are available.
NOTES: Only Duress/Guard, Master Manager and Engineer codes can be changed by the engineer. User
codes can only be changed by the Master Manager from the Master Manager menu. The Master User and
Engineer Codes cannot be deleted.
User
Arm and Disarm System. Also for Access Control and Sub
Area Control functions
Manager
Arm and Disarm System. Also access to Manager menu
Default: 1234
functions
Engineer
Access to all engineering functions; also arm/disarm
Default: 9999
system for test purposes.
Duress
Disarm system, generating silent 'Duress' signal.
Guard
Disarm system, but only after an alarm has been active
for a minimum time (programmable). Also arm system.
An output type is available to activate whenever this code
is used.
5.1.1 Change Duress/Guard Codes?
Choose Code Number
If a code or tag is already allocated, the display will show [******]. Press the  key to clear the
code.
Choose Code Number
The user type can be Duress [2] or Guard [3].
5.1.2 Duress Code
The Duress code can arm or disarm the system and if used a Duress communication event will be
sent. An output type is available to activate whenever this code is used (Duress type 008 - see page
12 - 13 Program Outputs).
User In Area
Choose the area(s) the code is active in
User In Area
User Arm Options
[0] Disarm/Arm: The code will arm and disarm the areas selected in the previous option.
[1] Disarm Only: The code will only disarm the areas selected in the previous option.
[2] Arm Only: The code will only arm the areas selected in the previous option.
[3] None: No option programmed.
PCX 46 Programming Reference
PCX 46 App
User Type
within that period will cause a
Page: 18
0-99
hours
0-100
seconds
0-734
Programmed by
Manager only.
Programmed by
Manager or Engineer.
Programmed by
Engineer.
Programmed by
Engineer.
Programmed by
Engineer.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PCX 46 App and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents