been called, the second number will be called. The two numbers will be alternated as many times as
the redials are set to. If a call has been acknowledged by the monitoring station then the panel will
stop calling.
Timeout: This is the time in seconds before a call times out from not being answered/received.
Test Calls:
The test call is used to show that the system is still alive when no activations have been made.
Setting up a test call asks for a start time in hours and minutes and the frequency of the call in days,
hours and minutes.
Event Types: Please see page: 34 for all event options. If 'Custom' is selected, all event types can be
chosen.
SMS Common Message:
This message will always be sent as part of the SMS activation text.
v. Advanced Comms
Prefix Tel No: This option only appears if a PSTN (Digi-1200) modem is installed. It allows you to
enter a number or series of numbers that will prefix all outgoing calls. For example, a lot of telephone
systems require a '9' adding to the beginning of a number so that an external call can be made from
an internal extension system.
Wait Dial Tone: Allows a dial tone to be transmitted or not for compatibility with different
telecommunications equipment (This option only appears if a PSTN (Digi-1200) modem is installed).
Send Events UDL: This option enables or disables the sending of system events via the Insite UDL
software.
Modem Tel no: One telephone number can be entered for each of the UDL PCs associated with your
alarm system.
Send Alarms/Faults/Open/Close/Access Ctrl: - The following menus allow you to enable or disable the
event categories/types that are sent via UDL.

5.1 Options Up/Downloading?

The system can be programmed from the keypad or the InSite UDL Software. There are 2 methods of
connection for programming the panel via the UDL Software:
1) Via the RS232 input locally;
2) Remotely GPRS, PSTN or LAN modems.
The UDL InSite Software allows the servicing and monitoring of the system and review of the logs.
RM Service: The Remote Maintenance Service is an automatic service performed by the panel and the
InSite UDL Software. This service enables the panel to automatically call a PC with the InSite UDL
software installed and deliver all diagnostics data to that PC. In this way the installer does not have to
visit the site to measure all the required measurements. This information could be used for creation of
regular technical reports to send to users as a proof for maintenance of the site.
Technical Alarms Monitoring
It is possible to program the panel to call the UDL InSite Software when alarms, faults, arm/disarm and
access control events are generated to up to 4 PCs running the UDL InSite Software.
5.1.1 UDL Connection to panels
RS232, Local Connection
The RS232 is used to program the panel locally connecting it to a PC running the UDL Software via a
special cable. If this option is chosen no other programming is required.
Modem, Remote Connection
The modem (PSTN/GPRS/LAN) is used to program the panel remotely connecting it to a PC running
the UDL Software via data modem.
Dial Mode Option (when 'modem' selected)
This function programs the procedure used for the call between PC and panel:
Auto Answer: When called from a PC the panel will answer the call immediately.
Dial Back: When called from PC the panel will take the line, disconnect and call the PC.
Panel Dials: Does not allow the PC to dial into the panel. A call has to be initiated by the user or
engineer from the panel.