WAGO-SPEEDWAY 767
767-5204 MOVILINK® Interface (RS-232, RS-485)
Example 2:
Interface 1 is connected to several MOVILINK
are configured as slaves with addresses 1 and 2 and as a group with address 101.
Output status:
PD1
PD1 (invalid)
The PLC writes user data PD1 ... PD3 and slave address 1 to the output process
image. The interface is in initialization status (status byte = 63).
Step 1:
PD1
PD1 (invalid)
By setting the flow control, cyclic transmission of the MOVILINK
permitted.
Step 2:
PD1
PD1 (valid)
Slave 1 has responded correctly. The slave address is written from the module to
byte 7 of the input process image. Setting the status byte (return code 1, "No
error") shows that there is valid MOVILINK
input process image.
Manual
Version 1.1.0
Output data
PD2
Input data
PD2 (invalid)
PD3 (invalid)
Output data
PD2
Input data
PD2 (invalid)
PD3 (invalid)
Output data
PD2
Input data
PD2 (valid)
MOVILINK® Interfaces
®
converters, where the converters
Flow control
PD3
locked
Status
= 63
initialization
Flow control
PD3
enable
Status
= 63
initialization
Flow control
PD3
enable
Status
PD3 (valid)
no error
®
user data in bytes 0 ... 3 of the
81
Slave address
= 0
= 1
Slave address
invalid
Slave address
= 1
= 1
Slave address
invalid
®
telegrams is
Slave address
= 1
= 1
Slave address
= 1
= 1