44
Connecting Data and Supply Cables
Pos : 24.12 /Serie 767 ( WAGO-SPEED WAY)/Ansc hluss D aten- und Versorgungs kabel/I/O-M odule/Ansc hlus s_S-BU S allgemein @ 5\mod_1249287447062_21.doc x @ 39873 @ 2 @ 1
5.3

Connecting the S-BUS Cables

The S-BUS is used for communication between a fieldbus coupler and the
connected 767 Series components.
Requirement:
A WAGO S-BUS cable pre-assembled on both ends is readily available to
you. This is necessary for optimal signal transmission.
The S-BUS terminator is available to you, which is necessary for
communication.
The following table outlines the assignment of the S-BUS connections:

Table 23: S-BUS connection assignment

Connection
IN
767-5204 MOVILINK® Interface (RS-232, RS-485)
Contact
OUT
1
2
3
4
5
Connecting thread Shield
WAGO-SPEEDWAY 767
Description
IN
OUT
RD +
TD +
RD −
TD −
TD −
RD −
TD +
RD +
GND
Manual