Connecting Sensor/Actuator Cables; Table 26: Digital Inputs And Outputs: Pin Assignment - WAGO MOVILINK SPEEDWAY 767 Manual

Rs-232, rs-485, 2 interfaces 2 x m12 + 4 digital inputs/outputs 2 x m12, two inputs/outputs per connector
Table of Contents

Advertisement

WAGO-SPEEDWAY 767
767-5204 MOVILINK® Interface (RS-232, RS-485)
Pos : 24.28 /Serie 767 ( WAGO-SPEED WAY)/Ansc hluss D aten- und Versorgungs kabel/I/O-M odule/Ansc hlus s_Sens oren/Aktoren 767- 5203, - 5204_4xM12 @ 11\mod_1327399614624_21.doc x @ 86922 @ 2 @ 1
5.6

Connecting Sensor/Actuator Cables

The sensor/actuator cable provides power to the connected sensors and actuators.
When using cables that have not been pre-assembled, make sure that these cables
are equipped with M12 plugs rated to IP67. The following table outlines the
assignment of the sensor/actuator connections:

Table 26: Digital inputs and outputs: Pin assignment

Connection
IN/OUT
X1
The highest current carrying capacity of the supply contacts is 4A!
Ensure that the actuators from the U
actuator's power consumption must be taken into consideration when determining
the current power demand for the V
Inputs/outputs have limited feedback protection!
Please note the maximum feedback current of 1A per input/output pin. It is
strongly recommended to feed input signals from U
Pos : 24.29 /D okumentati on allgemei n/Gli ederungsel emente/---Seitenwec hs el--- @ 3\mod_1221108045078_0.doc x @ 21810 @ @ 1
Manual
Version 1.1.0
Connection Scheme
IN/OUT
X2
A
Connecting Data and Supply Cables
supply line are supplied with power. The
A
supply line.
.
A
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

767-5204

Table of Contents