LCM Error Codes

If an error condition exists, the front Panel LED will blink the number of times corresponding to the error code number,
pause, then repeat. After the user acknowledges the generated error screen, the error number will appear on the bot-
tom left-hand side of the main run screen, and the described blink sequence will continue. If more than one error is
present, all will be presented, separated by commas. When the condition is cleared, the corresponding error number
will be removed from the main run screen. If an error code is present, the machine will not dispense.
Code
Name
E3
Improper
Machine Cali-
bration
E4
Bad Linear
Position Sen-
sor
E5
Stuck key
334135B
Type
Causes
Alarm
Machine has not been
calibrated or has been
calibrated incorrectly.
Alarm
1. Connection to position
sensor disconnected.
2. Power to position sen-
sor interrupted.
3. Bad position sensor.
Alarm
1. Key is in an active
state.
2. Tactile switch on LCM
is shorted or broke.
Fixes
Perform pump position
entries in Position Calibra-
tion Screen. Retract posi-
tion must be less than
metering tube position, which
should be less than the fully
extend position.
1. Verify connections to the
sensor.
2. Verify proper readings from
sensor on setup screen 1.
3. Replace sensor
Replace LCM Module.
Troubleshooting
Trigger
Condition
When
requesting a
dispense
operation.
Invalid read-
ings from the
sensor.
If key is
detected to
be active for
more than 30
seconds.
39