Oracle SPARC T5-1B Service Manual page 34

Server module
Table of Contents

Advertisement

Check for Faults
Manufacturer
: Oracle Corporation
Name
: SPARC T5-1B
Part_Number
: 7023631-04
Serial_Number : 465769T+1219EK001X
 
----------------------------------------
Suspect 1 of 1
Fault class : fault.memory.dimm-ue
Certainty
: 100%
Affects
: /SYS/MB/CM0/CMP/BOB6/CH1/D0
Status
: faulted but still in service
 
FRU
Status
Location
Manufacturer
Name
Part_Number
Revision
Serial_Number
Chassis
 
Description : Description associated with fault.memory.dimm-ue
 
Response
: Response associated with fault.memory.dimm-ue
 
Impact
: Impact associated with fault.memory.dimm-ue
 
Action
: Use 'fmadm faulty' to provide a more detailed view of this
event. Action associated with fault.memory.dimm-ue Please
refer to the associated reference document at
http://support.oracle.com/msg/SPSUN4V-8000-F2 for the latest
service procedures and policies regarding this diagnosis.
In this example, a fault is displayed, indicating these details:
Date and time of the fault (2013-01-08/12:13:42).
UUID (59b2d926-4896-e979-e85c-cfedb5daedf5), which is unique for every fault.
This is sometimes identified as an Event ID.
Message identifier (SPSUN4V-8000-F2), which can be used to obtain
additional fault information.
Faulted component, including these details:
34
SPARC T5-1B Server Module Service Manual • February 2019
: faulty
: /SYS/MB/CM0/CMP/BOB6/CH1/D0
: Samsung
: 8192MB DDR3 SDRAM DIMM
: 07042208,M393B1K70DH0-YK0
: 02
: 00CE0212133341DB80

Advertisement

Table of Contents
loading

Table of Contents