Input Voltage
Exciter Voltage
Antenna Tuning
Antenna Current
Tuning Capacitors
Tuning Phase
Tuning Relative Phase
FDXB Signal Level
Temperature
Sync. Input Present
Sec. Master Active
Active Alarms
Example
INF: Start Of Full Status Report
Reader:
ID:
Model:
S/N:
Date:
Time:
Application Firmware Version:
Operation Mode:
Network Mode:
Exciter Sync. Mode:
Date/Time Sync.:
Beeper:
Tag Display Format:
Initiation Delay:
Reader Auto Standby Voltages:
Periodic Standby Start Time:
Periodic Standby Duration:
Idling Time:
Alarms:
Antenna Current Low Alarm:
Noise High Alarm:
Tuning Capacit. High Alarm:
Tuning Capacit. Low Alarm:
Alarms Unique Delay:
Antenna/Tuning:
Exciter Voltage Level:
Dynamic Tuning:
Tuning Target Phase:
Tuning Target Phase Deviation Threshold
Communication:
Local Port Speed:
Tags To Local Port:
Alarms To Local Port:
IS1001 Reader User Manual
Measured input voltage in Volts DC
Measured exciter voltage in Volts DC
Antenna tuning status (Tuned/Tuning/Out Of Tune)
Measured antenna current in Amperes peak-to-peak
Antenna tuning capacitance setting (0 – 1023)
Measured tuning phase
Measured tuning relative phase
Measured FDX-B signal strength in milliVolts peak-to-peak and in percent
Measured reader temperature in degrees Celsius
Exciter synchronization input signal presence (Yes/No/N/A)
Exciter synchronization Secondary Master status (Yes/No/N/A)
Contains the list of all active alarms
IS1001
1915.0902
06/05/2019
09:52:56
IS1001 Standalone
Sec. Master
Disabled
Disabled
Disabled
16 V, 18 V
Disabled
Disabled
3600 sec
Enabled
115200
Enabled
Enabled
01
1.7.0
Scan
HEX
0:00
1.0 A
20%
970
50
1
382
3