Commands
ATP
{300-500}
ATS
{2-63}
AVE
{1-5}
Communication
CAL
{1|0}
CML
{1|0}
CPR
{A|M}
30
only be considered if a high-precision tune is required. In this case
you can set up any value of the tuning capacitors and check the
read performance. When the desired read performance is achieved,
note the corresponding measured phase and set this value as the
target phase for the IS1001 reader.
Set Dynamic Tuning Target Phase
Used to set or adjust the dynamic tuning target phase. Valid values
are 300 – 500. Default is 390.
This value is determined and set automatically during the Antenna
Full Tune process.
Note: Changing target phase manually should only be considered if
a high-precision tune is required. In this case you can adjust target
phase value to see if better read performance can be achieved.
Set Dynamic Tuning Target Phase Deviation Threshold
Used to set or adjust the tuning phase deviation threshold. Valid
deviation values are 2 – 63. Default is 10.
This specifies how far the actual antenna signal phase can deviate
from the target phase before the IS1001 reader begins the dynamic
auto-tune process. During this process the IS1001 reader adjusts
capacitance in an effort to return to the target phase and retune its
antenna.
This value is determined and set automatically during the Antenna
Full Tune process.
Note: In low Q systems you might set the Phase Deviation rather
high (10 or more). But beware of setting the deviation value so high
that the IS1001 reader is not making any adjustments at all or so
low that the reader is not able to maintain the tune point.
Set Exciter Voltage Level (Not available with model IS1001-12V)
Sets the exciter voltage level to adjust the antenna output power
(current). Valid values are 1 – 5. Default is 1.
Set Alarms Communication to Local Port {1} On, {0} Off
Specifies if alarms issued are sent to the local USB communication
port. Valid options are either On or Off. Default is On.
Set Messages Communication to Local Port {1} On, {0} Off
Specifies if messages issued are sent to the local USB
communication port. Valid options are either On or Off. Default is
On.
Set Remote Communication Port Protocol {A} ASCII, {M} MODEM
Sets the communication protocol of the remote communication port.
Valid options are ASCII or MODEM. Default is ASCII.