Biomark IS1001 Operation User's Manual page 40

Standalone
Hide thumbs Also See for IS1001:
Table of Contents

Advertisement

Commands
RNM
{S|M}
ROM
{1|0|R}
RPS
{SS,DD}
RSM
{1|2|3|0}
36
HDX Tag Detection is enabled. Valid values are 0 (disabled), 1 –
10000 milliseconds. Default is 0 (disabled).
Set Reader Network Mode {S} IS1001 Standalone, {M} MTS Node
Switches the IS1001 reader to either Standalone network operation
mode or MTS Node mode (in MTS Node mode the IS1001 reader
is controlled by a Master Controller). Default is IS1001 Standalone
mode.
Set Reader Operation Mode {1} Scan, {0} Standby, {R} Reset
Sets the IS1001 reader into either Scan mode, Standby mode, or
performs a reset.
Set Reader Periodic Standby: {Start Hours (00-23), Duration (00-
23)}
Sets at what hour of a day and for how many hours to automatically
switch the IS1001 reader into Standby mode to save power during
periods of inactivity. Default is 00,00 (disabled).
Set Reader Exciter Synchronization Mode {1} Master, {2}
Secondary Master, {3} Slave, {0} Standalone
Sets the IS1001 reader exciter synchronization mode. Valid values
are Master, Secondary Master, Slave and Standalone. Default is
Secondary Master.
If set to Master, the IS1001 reader will use its own antenna exciter
oscillator as the source of the synchronization signal and will
transmit it out to the synchronization network. If the unit is put in
standby mode its synchronization output signal is disabled. In this
mode, if HDX tag detection is enabled, FDX/HDX cycle timings will
be fixed to the present setting of the FDXB Detection Scan Time
parameter for FDX, and to 20 milliseconds for HDX.
If set to Secondary Master, the IS1001 reader will assume the
Master role and will enable its own antenna exciter oscillator if it did
not detect the presence of synchronization signal on the
synchronization network, otherwise it will operate as a Slave and will
use antenna exciter oscillator signals received through the
synchronization network.
If set to Slave, the IS1001 reader will disable its own antenna exciter
oscillator and will use the synchronization signal it receives through
the synchronization network.
If set to Standalone, the IS1001 reader will use its own antenna
exciter. In this mode, if HDX tag detection is enabled, FDX/HDX
cycle timings will be variable depending on a tag presence in the
antenna field: from 45 milliseconds to the present setting of the
FDXB Detection Scan Time parameter for FDX, and from 4 to 20
milliseconds for HDX. Even though the synchronization signal will
still be transmitted out to the synchronization network, this mode
must not be used when multiple IS1001 readers are being
synchronized.